Select Items And Analog Data - Mitsubishi LE-40MTB-E Instruction Manual

Tension controller
Table of Contents

Advertisement

11.4 Selection item and analog data
1. Selection item
Set item
Control while stop timer
Unit of tension
Control reel
Number of reels
Taper control
Taper signal
Taper mode
Actuator
Stall reset
AI2/AI3 setting
MC5/MC6 setting
Number of detectors
Pc-link
Automatic gain
Registration of menu titles
*1 : Refer to the note in the previous page.
*2 : Setting of MC5, MC6
When the control reel is set to one reel or the feed reel, never set the [cut torque] to MC5 or MC6.
Set the [cut torque] exclusively when multiple reels are selected.
*3 : Setting of AI2, AI3
When the control reel is set to the feed reel, never set the[taper ratio]or the[diameter] to AI2 or AI3.
Set the[taper ratio] or the[diameter] exclusively when the control reel is set to[winding] or[unwinding]
When the taper signals set to [external], make sure to set the winding diameter to AI2 or AI3.
When the control reel is set to one reel or the feed reel, never set the [new reel preset] to AI2 or AI3.
Set the [new reel preset] exclusively when multiple reel are selected.
*4 : The setting of the item marked with "
while th MC1 input is turned on.
2. Analog data
Name
Manual torque
Tension setting
Tension
setting(AI1)
Tension detec-
tor
(auxiliary)
Taper ratio
setting
Stall setting
New reel preset
Diameter input
• These inputs are always valid even if set screen is not displayed.
• These analog values are digitized by 12-bit A/D converter.
3. Monitor data
The monitor data contains the following items, and is not saved if power is interrupted.
• Tension monitor, total( N,x10N)
• Tension monitor, left (N,x10N)
• Tension monitor, right (N,x10N)
• Control output(0~100%)
-------- The items cannot set during operation.
Description
feed back / Fixed
×10N / N
Unwinding / Winding / Feed
One reel / Multi reels
OFF / ON
Internal / External
Linear / Nonlinear
Powder / Servo
MC4 / MC4+OUT SW.
Diameter / Stall / New reel preset
/ Taper ratio / Ext. tension
Gain 2 / Inching / OUT remote
/ Cut torque / Ext. tension
2 / 1
Unuse/FX-parallel/NET/MINI/CC-link
Automatic / Manual
Menu mane of the menu1~menu7.
×
" on the " Setting during operation " column cannot be canged
Unit
Digital data for analog value of 0~5V
%
0 ~ 100
N
0 ~ full scale tension
×10N
N
0 ~ full scale tension
×10N
N
0 ~ full scale tension
×10N
0 ~ 80%(0=Set tension):Int.diameter
%
0 ~100%(0=Set tension):Ext.diameter
%
0 ~100%
%
0 ~100%
mmφ
min. diameter ~ max. diameterÅÖ2000
Initial set
feed back
N
Unwinding
One reel
OFF
Internal
Linear
Powder
MC4+OUT SW.
Not set
Not set
2
Manual
Increment
• Tension, target (N,x10N)
Value based on the set tension while taking the
decrease ratio of the taper tension into account.
• Reel diameter input(min. diameter ~ max. diameter)
72
*4
Memory *1
Setting
during
Menu System
operation
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Remark
1
1
0.1
1
0.1
1
0.1
1
Terminals AI2 and AI3
are set by parameters.
1
1
11
Mainly
refer
page
26
8
9
9
29
29
30
9
14
68
*2
67
*3
9
47
32
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents