7. Example of program
After the data processing is completed in the LE-40MTB-E, the X0 is turned on while the M907 is turned
off, then all set value are transferred at a time to the temporary buffers for link.
After the data processing is completed in the LE-40MTB-E, the X1 is turned on while the M907 is turned
off, then the set values other than X1=ON are transferred to the temporary buffers for link.
When the X0 is turned on, the data is transferred from the temporary buffers for link D0Å`D10 to the link
data transfer area D490Å`D499, then the sending start flag M807 is turned on.
When the receiving completion flag M907 is turned on by the LE-40MTB-E, sending is completed.
M8000
0
X000 M906
3
X001 M907
53
X010
107
M0
111
M907
123
CIRCUIT END
( M8070 )
K
MOV 50
D0
H
MOV 0009 D1
K
MOV 54
D2
H
MOV 0004 D3
K
MOV 56
D4
K
MOV 500 D5
K
MOV 57
D6
H
MOV 0004 D7
H
MOV 0000 D8
H
MOV 0000 D9
K
MOV 1
D0
K
MOV 250 D1
K
MOV 2
D2
K
MOV 20
D3
K
MOV 15
D4
K
MOV 25
D5
K
MOV 16
D6
K
MOV 50
D7
K
MOV 20
D8
K
MOV 120 D9
M807
[ PLS M0 ]
M907
BMOV D 0 D490 10
[ SET M807 ]
[ RST M807 ]
[ END ]
53
Master station
Setting of the memory
switch 1
Unit = N, multi reels control.
Setting of the
MC5
OUT remote
Setting of the fill scale
tension
500
Setting of the decimal point of the full scale
tension
×0.1
The data is not transferred
Data 0
Tension setting
25.0N
Stall setting
20%
Manual setting
25%
Start timer setting
5.0 s
Gain 1 setting
120%
The link data is transferred to the buffer
K
End of program