Description Of Minor Errors Of The Ehr-B Electro-Hydraulic System; Outer Hydraulic Circuit - Zetor Proxima GP Series Operator's Manual

Hide thumbs Also See for Proxima GP Series:
Table of Contents

Advertisement

Description of minor errors of the EHR-B electro-hydraulic system

Flashing combination of
the diagnostic LED (7).
No.
Long
Short
of
pause
pause
flashes
3x
3x
3x
3x

Outer hydraulic circuit

It supplies pressure oil for hydraulic devices on outer
drives of hydraulics ended with couplers. Coupler sockets
with 12.5 mm bore are in accordance with the international
recommendation of ISO.
ELECTRO-HYDRAULIC SYSTEM
Error location
No.
of
flashes
1x
Right dynamometric pin
(A)
2x
Left dynamometric pin (A) Faulty contact or interrupted conductor of the
4x
Lowering speed control
(3)
6x
Control setting switch (6)
F_02_174
Possible cause of the error
Faulty dynamometric pin
dynamometric pin
Short-circuit of the dynamometric pin
conductor
Possible overloading of the dynamometric
pin
Faulty potentiometer of the control (3)
Faulty contact or interrupted conductor of the
control
Faulty potentiometer of the switch (6)
Faulty contact or interrupted conductor of the
switch
96
P+13N011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proxima gp 80Proxima gp 90

Table of Contents