6.5

Setting the zero point of the needle stroke setting

Fig. 7: Needle stroke setting
1.
Close the air feed.
2.
Turn the adjustment nut ( Fig. 7/1) by turning clockwise.
3.
Open material supply.
4.
Open the control air feed.
5.
Slowly open the adjustment nut ( Fig. 7/1) turning anti-clockwise until fluid escapes.
6.6

Shut-down

6.6.1 Temporary shut-down
End the spray procedure by switching off the control air (connection "St").
The atomiser air (connection "Z") is automatically closed in the automatic spray gun.
6.6.2 Long-term shut-down
1.
Close the air supply for control air and atomiser air (
on page 18).
2.
Close the material supply and switch off the pump if necessary.
3.
If necessary, clean the spray gun (
on page 29).
GB–26
Operating instructions
Ä Chapter 5.3 'Connection scheme'
Ä Chapter 7.2 'Cleaning automatic spray gun'