Selection Description
Identity
Vendor
Product
Firmware Version
Modbus
Modbus Baud Rate (kbps)
Is Modbus Master?
Modbus Slave Address
Modbus Timeout Factor (1--fast, 10 slow)
Received Modbus Message Count
Modbus Error Count
Product Connections
Connected GenSet Product
Connected GenSet Address
Connected GenSet Timeout
Connected ATS Product
Connected ATS Address
Connected ATS Timeout
Connected (Slave) Annunciator 1 Product
Connected (Slave) Annunciator 1 Address
Connected (Slave) Annunciator 1 Timeout
Connected (Slave) Annunciator 2 Product
Connected (Slave) Annunciator 2 Address
Connected (Slave) Annunciator 2 Timeout
Connected (Slave) Annunciator 3 Product
Connected (Slave) Annunciator 3 Address
Connected (Slave) Annunciator 3 Timeout
Connected (Slave) Annunciator 4 Product
Connected (Slave) Annunciator 4 Address
Connected (Slave) Annunciator 4 Timeout
Connected (Slave) Annunciator 5 Product
Connected (Slave) Annunciator 5 Address
Connected (Slave) Annunciator 5 Timeout
Product Connections Inputs
EPS Supplying Load Indicator
Digital Input 1 Source
Digital Input 1 Event Level
Digital Input 2 Source
Digital Input 2 Event Level
Digital Input 3 Source
Digital Input 3 Event Level
Digital Input 4 Source
Digital Input 4 Event Level
Digital Input 5 Source
Digital Input 5 Event Level
* Controller List includes:
Decision-Makerr 3+, 550, 3000, 3500, 6000, 8000, APM802, or KPC 1000.
[ ATS List includes: None, MPACr 750, MPACr 1000, MPACr 1200, or MPACr 1500.
] Annunciator List includes: None, RSA 1000, RSA II, or RSA III.
w The SiteTecht software may have a different default setting for selected devices.
Figure 55 User-Defined Settings
TT-1625 7/17
Display or Default
Selection
Kohler Company
RSA III
1.0.9
19.2
9.6, 19.2, 38.4, or 57.6
True
246
5
#
#
none
1
45 seconds w
none
2
45 seconds w
none
See Annunciator List ]
3 (If RSA 1000, then 247)
45 seconds w
none
See Annunciator List ]
4 (If RSA 1000, then 247)
45 seconds w
none
See Annunciator List ]
5 (If RSA 1000, then 247)
45 seconds w
none
See Annunciator List ]
6 (If RSA 1000, then 247)
45 seconds w
none
See Annunciator List ]
7 (If RSA 1000, then 247)
45 seconds w
Generator
Local
Warning
Local
Warning
Local
Warning
Local
Warning
Local
Warning
Setting Range
Lamp
True or False
1--247
1--10
See Controller List *
1--247
1--120 seconds
See ATS List [
1--247
1--120 seconds
1--247
1--120 seconds
1--247
1--120 seconds
1--247
1--120 seconds
1--247
1--120 seconds
1--247
1--120 seconds
Local (hardwired),
Generator, or ATS
Local (hardwired),
Generator, or ATS
Warning--Yellow,
Warning or Fault
Fault--Red
Local (hardwired),
Generator, or ATS
Warning--Yellow,
Warning or Fault
Fault--Red
Local (hardwired),
Generator, or ATS
Warning--Yellow,
Warning or Fault
Fault--Red
Local (hardwired),
Generator, or ATS
Warning--Yellow,
Warning or Fault
Fault--Red
Local (hardwired),
Generator, or ATS
Warning--Yellow,
Warning or Fault
Fault--Red
Alarm
User-Defined
Horn
Settings
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Yes (if
Fault)
Yes (if
Fault)
Yes (if
Fault
Yes (if
Fault
Yes (if
Fault