7

Gas Information

A. Fuel Conversion
• Make sure the appliance is compatible with available gas
types.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specified
and approved parts.
• Reference the following diagrams for gas shut off detail
and component access.
• Reference Section 9.A to remove fixed glass assembly.
NOTE: The gas ball
valve is in the "OFF
position from
manufacturer.
NOTE: Use the Multi-Purpose
Tool to assist with gas shut-off.
GAS SHUT OFF
Figure 7.1 Gas Shut-off
• Use multi-purpose tool to assist with gas shutoff. See
Figure 7.1. The gas ball valve is in the "OFF" position
from manufacturer.
• Glass clip assemblies can be removed for additional
component accessibility.
NOTE: Bottom right glass clip on 25 inch models must
be removed to gain access to controls.
BASE REFRACTORY
GLASS CLIP
ASSEMBLIES
Figure 7.2 Glass Clip Assembly Removal
Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19
OFF POSITION
(TURN KNOB CLOCKWISE)
MULTI-PURPOSE TOOL
GLASS
CLIP ASSEMBY
SCREW ACCESS
PRESS
TAB TO
RELEASE
UNCLIP
WIRES
GLASS SEAL PLATE
Figure 7.3 Component Tray
WARNING! Glass seal plate must be properly installed.
Risk of elevated component temps and carbon monoxide
exposure.
CAUTION: Be sure to reinstall the component heat shield
before firing the appliance. Components will overheat.
COMPONENT
TRAY RECEIVER
COMPONENT
TRAY