Quadra-Fire EXCURSION-I Owner's Manual
Hide thumbs Also See for EXCURSION-I:

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions regarding installation, operation or service.
NOTICE: DO NOT discard this manual!
Models:
EXCURSION-I
EXCURSION-II
EXCURSION-III
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner's Manual • 2538-981 Rev. B • 2/19
Owner's Manual
Care and Operation
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See appliance installation manual for additional
Commonwealth of Massachusetts requirements.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EXCURSION-I and is the answer not in the manual?

Questions and answers

Summary of Contents for Quadra-Fire EXCURSION-I

  • Page 1 See appliance installation manual for additional gases, unless a certified kit is used. Commonwealth of Massachusetts requirements. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 2: Welcome

    00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 3: Table Of Contents

    C. Contact Information ......34  = Contains updated information. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 4: Limited Lifetime Warranty

    Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 6: Product Specific Information

    B. Glass Specifications This appliance is equipped with 5 mm ceramic glass. Re- place glass only with 5 mm ceramic glass. Please contact your dealer for replacement glass. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 7: Important Safety And Operating Information

    • Keep remote controls out of reach of children. Figure 3.1 Clear Space Requirement - All Models • Never leave children alone near a hot fireplace, whether operating or cooling down. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 8: General Operating Parts

    For APPLIANCE SURROUND additional finishing guidelines, see Section 8 Installation Manual. Figure 3.3 Good Faith Wall Surface Temperatures Above Appliance Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 9 Sugges ons on how to further reduce TV temperatures: Increase “A” dimension. Increase “C” dimension, however, increasing “B” dimension beyond maximum recommended typically results in higher temperatures. Figure 3.4 Good Faith TV Guidelines Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 10: Before Lighting Appliance

    • Verify collar slide plate screw is attached see Figure 3.5. BE SURE SLIDE PLATE SCREW IS FULLY TIGHTENED. Figure 3.5 Collar slide Plate Screw Detail Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 11: Lighting Instructions (Ipi)

    Propane Installation code, CSA B149.1. P65Warnings.ca.gov. For additional information on operating your Keep burner and control compartment clean. See installation and operating instructions accompanying appliance. refer to www.hearthnhome.com. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 12: Appliance Break-In

    NOTICE! Open windows for air circulation during fire- place break-in. Figure 3.6 Glass Seal Plate • Some people may be sensitive to smoke and odors. • Smoke detectors may activate. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 13: Heat Management

    “OFF”. See Figure 3.9. Check to make sure the ignition module switch is NOT in the “ON” position. • Resume normal operation with the RC400. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 14 IFT-RC400, IFT-RC150 or wired wall switch. 2. If multiple control options are installed, the IFT-ECM will respond to the last command from the wired wall switch, IFT-RC400 or IFT-RC150. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 15 If the IFT-ECM re-enters the lock-out condition after these steps, call your dealer for service. SURROUND RESET SWITCH Figure 3.9 Surround Reset Switch Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 16: Maintenance And Service

    CAUTION! Risk of Burns! The fireplace should be turned off and cooled before servicing. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 17 Verify top latches are fully engaged and then fasten the Figure 4.3 Glass Seal Plate two bottom latches using the supplied multi-purpose tool. • Reinstall door or decorative front. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 18 GLASS SEAL PLATE COMPONENT TRAY WITH HEAT SHIELD Figure 4.4 Component Tray Access CAUTION: Be sure to reinstall the component heat shield before firing the appliance. Components will overheat. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 19: Maintenance Tasks - Qualified Service Technician

    • Verify that the collar slide plate screw is installed. See Figure 3.5. • Remove all foreign objects. • Verify unobstructed air circulation. • Ensure no wire connections become disengaged. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 20 • Verify that there is not a short in flame sense circuit by checking continuity between pilot hood and flame sensing rod. Replace pilot as necessary. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 21: Frequently Asked Questions And Troubleshooting

    (4 AA batteries required). Refer to Section 3.I for more details. Contact your dealer for additional information regarding operation and troubleshooting. Visit www.quadrafire.com to locate a dealer. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 22: Frequently Asked Questions - Intellifireā„¢ Touch Controls

    Install new batteries in battery backup (4 AA batteries re- Power outage. Error.” quired). Contact your dealer for additional information regarding operation and troubleshooting. Visit www.quadrafire.com to locate a dealer. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 23: Troubleshooting

    If open or shorted, replace valve. Check valve harness wire continuity, if open replace 6-pin harness. Pilot won’t light, there is no noise Spark coil failure. Replace ECM. or spark, 2 Red/2 Green Lockout. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 24 Check resis- Damaged pilot assembly. tance between tip of sense rod and IFT-ECM connector, should be less than 1 ohm. Replace pilot assembly if damage is de- tected. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 25: Reference Materials

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative front. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 26: Service Parts

    B. Service Parts Beginning Manufacturing Date: March 2019 25” Gas Insert - DV Ending Manufacturing Date: Active Log Set Assembly Part number list on following page. 02/19 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 27 2537-014 Refractory Assembly SRV2537-076 Hearth Refratory SRV2537-703 Seal, Glass Frame 2531-122 Glass Door Assembly GLA-2531 Power Cord 2201-024 GFK-160A Additional service part numbers appear on following page. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 28 EXCURSION-II Service Parts Beginning Manufacturing Date: March 2019 30” Gas Insert - DV Ending Manufacturing Date: Active Log Set Assembly Part number list on following page. 02/19 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 29 2538-014 Refractory Assembly SRV2538-076 Hearth, Refractory SRV2538-703 Seal, Glass Frame 2532-122 Glass Door Assembly GLA-2532 Power Cord 2201-024 GFK-160A Additional service part numbers appear on following page. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 30 EXCURSION-III Service Parts Beginning Manufacturing Date: March 2019 35” Gas Insert - DV Ending Manufacturing Date: Active Log Set Assembly Part number list on following page. 02/19 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 31 2538-014 Refractory Assembly SRV2539-076 Hearth, Refractory SRV2539-703 Seal, Glass Frame 2533-122 Glass Door Assembly GLA-2533 Power Cord 2201-024 GFK-160A Additional service part numbers appear on following page. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 32 Tray, Component 2532-170 22.9 Wire Tray 2532-171 22.10 Wall Switch Jumper Wire SRV2179-300 22.11 Cable, B Type AC Module SRV2326-152 Additional service part numbers appear on following page. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 33 Pilot Ori ce Propane 593-526 Regulator NG NGK-DXV-50 Regulator Propane SRVLPK-DXV-50 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 3A fuse, 3/4” long Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...
  • Page 34: Contact Information

    6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7074035, 7098269, 7258116, 7322819, 7470729, 7726300, 8147240, 9625149 or other U.S. and foreign patents pending. 2000-945D Printed in U.S.A. - Copyright 2019 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner’s Manual • 2538-981 Rev. B • 2/19...

This manual is also suitable for:

Excursion-iiiExcursion-ii

Table of Contents