INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models: EXCURSION-I
EXCURSION-II
EXCURSION-III
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire EXCURSION-I

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 2: Table Of Contents

    G. Installing Termination Cap ......26  = Contains updated information. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________  = Contains updated information. (Builder / Gen. Contractor/) (Installer) (Date) 2538-982 11/18 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 4: Product Specific And Important Safety Information

    EXCURSION-III known to the State of California to cause cancer and (0-2000 FT) 35,000 24,500 (Propane) reproductive harm. For more information go to: www. P65Warnings.ca.gov. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 5: Getting Started

    Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified service technician, service agency or your dealer. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 6 OPTION C Multi-purpose tool can be stored in appliance manual bag. Figure 2.3 Multi-Purpose Tool Storage Options DO NOT store appliance manual bag in or around the appliance. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 7: Good Faith Wall Surface

    Stove cement / Aluminum foil tape 3/16 in. Allen wrench (Rear Leveling Legs) Elongated pressure taps (Recommended) Noncorrosive leak check solution Caulking material (300 ºF minimum continuous exposure rating) Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 8: Appliance / Fireplace Requirements And Clearances

    2-7/16 381 18-15/16 481 21-7/16 545 *Note: Location G is the appliance depth measurement, for installation depth reference Location E on Figure 3.8. Figure 3.1 Appliance Dimensions Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 9 14-3/4 3-1/4 19-1/2 EXCURSION-I FA-EXC25 15-3/16 3-1/4 23-1/2 EXCURSION-II FA-EXC30 19-3/16 3-1/4 26-1/2 EXCURSION-III FA-EXC35 1041 Figure 3.2 Decorative Front Dimensions - Forge Arch Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 10 27-5/16 12-1/16 3-1/4 19-1/2 EXCURSION-I TA-EXC25 32-5/16 15-9/16 3-1/4 23-1/2 EXCURSION-II TA-EXC30 33-9/16 18-13/16 3-1/4 26-1/2 EXCURSION-III TA-EXC35 1041 Figure 3.3 Decorative Front Dimensions - Tuscan Arch Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 11 26-1/4 14-1/2 31-1/4 19-1/2 EXCURSION-I MFV-EXC25 31-1/4 36-1/4 23-1/2 EXCURSION-II MFV-EXC30 36-1/4 21-1/2 41-1/4 26-1/2 EXCURSION-III MFV-EXC35 1048 Figure 3.4 Decorative Front Dimensions - Mission Full View Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 12 1-7/8 25-5/8 16-1/2 EXCURSION-I INFIT-25 27-5/8 16-1/16 1-7/8 30-5/8 20-1/2 EXCURSION-II INFIT-30 32-5/8 19-9/16 1-7/8 35-5/8 23-1/2 EXCURSION-III INFIT-35 Figure 3.5 Decorative Front Dimensions - Inside Fit Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 13: Minimum Fireplace Opening

    The original fireplace may never be returned to solid fuel in this condition. The sidewalls and top structure of the firebox may not be altered with the exception of removable baffles and dampers. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 14 On site custom surrounds are available. See your dealer for information. On site custom surrounds are flush and have no depth. A flush surround would increase the unit opening depth (E*) by 3/4 inch. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 15: Wall Extension

    Figure 3.9 Non-Combustible Framing Requirement this manual. Overlapping materials could ignite and will interfere with proper operation of decorative fronts. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 16 Note: Combustible materials may be used to seal wall extension to existing masonry wall as long as it is out- side the non-combustible zone. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 17: Mantel, Wall Projections, & Hearth Extensions

    Note: All numbers in Tables 1 and 2 include the 1/4 in. gap on Figure 3.13 Clearances to Mantel Legs or Wall Projections surround edge. (Acceptable on both sides of surround opening) Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 18: Hearth Extension

    REQUIRED. See side view in Figure 3.18. • Combustible flooring underneath the appliance is acceptable with a 1/4 inch gap. See Figure 3.18. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 19: Installation Preparation

    Right Side 25 in. 10 ft. 6 in. 8 ft. 30 in. 10 ft. 3 in. 7 ft. 6 in. 35 in. 10 ft. 7 ft. Figure 4.1 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 20: Installing Vent Pipe And Appliance

    VENT PIPE COLLAR SLIDE PLATE ASSEMBLY EXHAUST STARTING COLLAR NOTE: TO ACHIEVE OPTIMUM PERFOR- MANCE OF INSERT, MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE. Figure 5.1 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 21: Using Vertical Restrictor

    10 ft. - 20 ft. No adjustment needs to be done. 21 ft. - 35 ft. Open 1 restrictor opening. 36 ft. - 50 ft. Open both restrictor openings. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 22: Venting Components

    • Depending on the chimney cleanliness, consider using the full length intake so as to lessen the possibility of sense rod contamination and flame rectification issues. Figure 5.4 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 23: Connecting To Slp

    Up to four 45 degree elbows may be used as long as the minimum venting requirements are met per the above chart. Figure 5.5 Optional SLP Venting Configuration - Vertical Termination Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 24: Connecting Vent Pipe

    • Trim chimney top plate to minimize excess overhang or bend over flue tile. See Figure 5.6. • Place 3/8 inch bead of 300 ºF minimum continuous exposure rating silicone on flue tile top. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 25: Placing, Securing And Leveling The Appliance

    LOWER REAR LEVEL LEGS TO REDUCE GAP ABOVE SURROUND FLOOR Figure 5.7 Leveling Leg Detail Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 26: Installing Termination Cap

    Over 10/12 to 11/12 ..3.25 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 5.8 Minimum Height from Roof to Lowest Discharge Opening Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 27: Electrical Information

    NOTICE: DO NOT wire 110-120 VAC to wall switch. RECOMMENDED ELECTRICAL OUTLET LOCATIONS APPLIANCE Figure 6.1 Electrical Outlet Detail Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 28: Wiring Requirements

    BATTERY PACK SPLITTER 2187-198 2326-134 APPLIANCE ON/OFF CONTROL (OPTIONAL) HALOGEN BULBS (X 2) 2201-150 WSK-21-W NOT OFFERED WITH 25 in. MODELS Figure 6.2 IntelliFire™ Touch Wiring Diagram  Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 29: Installation / Service For Fan

    • Reattach flexible liner and replace collar slide plate screw. See Figure 5.1. OPTION 1 INSTALL FAN Figure 6.4 Through Valve Plate Opening (Option 2) REAR COVER PLATE Figure 6.3 Cover Plate Removed (Option 1) Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 30: Installation / Service For Halogens

    See Figure 5.1. OPTION 2 INSTALL HALOGENS OPTION 1 INSTALL HALOGENS REAR COVER PLATE Figure 6.6 Through Valve Plate Opening (Option 2) Figure 6.5 Cover Plate Removal (Option 1) Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 31: Gas Information

    CAUTION: Be sure to reinstall the component heat shield before firing the appliance. Components will overheat. BASE REFRACTORY GLASS CLIP ASSEMBY SCREW ACCESS GLASS CLIP ASSEMBLIES Figure 7.2 Glass Clip Assembly Removal Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 32: Gas Pressure

    1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Figure 7.4 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 33: High Altitude Installations

    Figure 7.6 Gas Valve Detail Figure 7.5 Air Shutter Air Shutter Settings Propane EXCURSION-I 3/16 in. 3/8 in. EXCURSION-II 3/8 in. Full Open EXCURSION-III 3/8 in. 1/2 in. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 34: Finishing

    Figure 8.1 Clearances to Mantel Legs or Wall Projections Note: All numbers in Tables 1 and 2 include the 1/4 in. gap on (Acceptable on both sides of surround opening) surround edge. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 35: Hearth Extension

    REQUIRED. See side view in Figure 8.6. • Combustible flooring underneath the appliance is acceptable with a 1/4 inch gap. See Figure 8.6. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 36: Appliance Setup

    • Reinstall door or decorative front. Figure 9.2 Glass Seal Plate WARNING! Glass seal plate must be properly installed. Risk of elevated component temps and carbon monoxide exposure. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 37: Remove The Shipping Materials

    WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 38: Refractory

    Figure 2 Empty Firebox Service Parts: If replacement panels are needed, the entire kit must be ordered. Figure 3 Base Refractory Installed Figure 1 Refractory Kit Components Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 39 3. Install left and right refractory, bend down tabs to hold in place. See Figures 5, 6 & 7. Figure 8 Refractory Kit Installed Figure 5 Left Refractory Installed 2532-936 Figure 6 Left Refractory Handbend Tab Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 40: Ember Rocks Placement

    • Save the remaining ember materials for use during Figure 9.4 Placement of Embers appliance servicing. The embers provided should be enough for 3 to 5 applications. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 41: Install The Log Assembly

    A and bark end touches left refractory. See Figure 4. GRATE BASEPAN 7/8 in. BASE REFRACTORY Figure 3. Side Profile Grate Location Reference Figure 4. Log #1 Installed Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 42 LOG #7: Notch on burnout end of Log #7 rests on grate tine, bark end rests on notch of Log #1. Slide burnout end of log back until it touches Log #4. See Figure 10. Figure 10. #7 Installed Figure 9. Log #6 Installed Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 43 Ensure that the cutout section of the log is pushed up against the side of the pilot hood. See Figures 14, 15 and 16. CUTOUT PILOT HOOD Figure 14. Log #1 Cutout Figure 15. Log #1 Against Pilot Hood Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 44 LOG #5: Place the burnout tip of Log #5 against pin C and the end of grate tine. Place the bark end on the flat spot of Log #3. See Figure 20. Figure 20. Log #5 Installed Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 45 LOG #7: Notch on burnout end of Log #7 rests on grate tine, bark end rests on notch of Log #1. Slide burnout end of log back until it touches Log #4. See Figue 23. Figure 24. Complete Log Set Figure 23. Log #7 Installed Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 46 LOG #2: Place the bottom right end of log #2 against pin F and the left end of the log on the flat spot of log #1. Push the log back so that it contacts the air scoop. See Figure 29. PILOT HOOD Figure 28. Log #1 Installed Figure 29. Log #2 Installed Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 47 LOG #6: Place the burnout tip of log #6 against pin D and the end of tine #3. Place the bark end in the notch on log #3. See Figure 35. Figure 34. Log #5 Installed Figure 35. Log #6 Installed Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 48 LOG #8: Notch on burnout end of log #8 rests on grate tine, bark end rests on notch of log #1. See Figure 37. Figure 36. Log #7 Installed Figure 37. Log #8 Installed. 2538-935 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 49: Install Decorative Front And Surround

    • Reset switch must be installed and in the “ON” position  for appliance to operate. NOTE: For on site custom surround details, see instruc- tions included with the surround. RESET SWITCH Figure 9.5 Surround Reset Switch Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 50: Appliance Break-In

    If this occurs, restart the appliance. NOTICE! Open windows for air circulation during fire- place break-in. • Some people may be sensitive to smoke and odors. • Smoke detectors may activate. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 51: Reference Materials

    FLEX3-30: One 3 inch flexible liner expands to 30 feet. FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...
  • Page 52: Accessories

    Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your nearest Quadra-Fire dealer, please visit www.quadrafire.com. Printed in U.S.A. - Copyright 2019 Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19...

This manual is also suitable for:

Excursion-iiExcursion-iii

Table of Contents