CW SETTING
- MODE CW -
AGC FAST DELAY
Function: Sets the AGC-FAST DELAY voltage
decay characteristics for CW mode.
Available Values: 20 - 4000msec
Default Setting: 160msec
Description: Sets the AGC voltage decay char-
acteristics in 20 msec steps after
the input signal level becomes lower
than the AGC detection level and the
HOLD time has expired.
AGC MID DELAY
Function: Sets the AGC-MID DELAY voltage de-
cay characteristics for CW mode.
Available Values: 20 - 4000msec
Default Setting: 500msec
Description: Sets the AGC voltage decay char-
acteristics in 20 msec steps after
the input signal level becomes lower
than the AGC detection level and the
HOLD time has expired.
AGC SLOW DELAY
Function: Sets the AGC-SLOW DELAY voltage
decay characteristics for CW mode.
Available Values: 20 - 4000msec
Default Setting: 1500msec
Description: Sets the AGC voltage decay char-
acteristics in 20 msec steps after
the input signal level becomes lower
than the AGC detection level and the
HOLD time has expired.
LCUT FREQ
Function: Sets the low-frequency cutoff audio fil-
ter in CW mode.
Available Values: OFF / 100Hz - 1000Hz
Default Setting: 250Hz
Description: The cutoff frequency can be set at
50 Hz increments between 100 Hz
and 1000 Hz.
LCUT SLOPE
Function: Sets the slope of the low-frequency
cutoff audio filter in CW mode.
Available Values: 6dB/oct / 18dB/oct
Default Setting: 18dB/oct
HCUT FREQ
Function: Sets the high-frequency cutoff audio
filter in CW mode.
Available Values: 700Hz - 4000Hz / OFF
Default Setting: 1200Hz
Description: The cutoff frequency can be set at
50 Hz increments between 700 Hz
and 4000 Hz.
HCUT SLOPE
Function: Sets the slope of the high-frequency
cutoff audio filter in CW mode.
Available Values: 6dB/oct / 18dB/oct
Default Setting: 18dB/oct
CW OUT SELECT
Function: CW signal output band setting from
RTTY/DATA jack.
Available Values: MAIN / SUB
Default Setting: MAIN
Description: Select the band to output the CW
signal.
CW OUT LEVEL
Function: Sets the level of the CW signal output
from the RTTY/DATA jack.
Available Values: 0 - 100
Default Setting: 50
CW AUTO MODE
Function: Enables/disables CW keying while op-
erating on SSB.
Available Values: OFF / 50M (50MHz) / ON
Default Setting: OFF
Description:
OFF: Disables CW keying while operating on
SSB.
50M: Enables CW keying while operating SSB
on 50 MHz (but not HF).
ON:
Enables CW keying while operating SSB
on all TX bands.
CW BK-IN TYPE
Function: Sets the CW brake-in function.
Available Values: SEMI / FULL
Default Setting: SEMI
Description:
SEMI: A brief delay is provided after the CW key-
ing operation, before the transceiver re-
turns to receive mode.
The receiver recovery time may be
changed using "CW BK-IN DELAY".
FULL: The transceiver immediately returns to re-
ceive mode after every CW key-up (QSK
mode).
CW BK-IN DELAY
Function: Sets the CW delay time.
Available Values: 30msec - 3000msec
Default Setting: 200msec
Description: The delay time can be changed be-
tween 30 msec and 3000 msec.