CAT RTS
Function: Configures the CAT RTS port setting.
Available Values: OFF / ON
Default Setting: ON
Description: Monitors the computer using the
RTS signal.
ON:
Monitors the computer status using the
RTS signal.
OFF: Disables the monitoring function.
QMB CH
Function: Number of channels setting of the
Quick Memory bank.
Available Values: 5ch / 10ch
Default Setting: 5ch
Description: Set the number of channels that can
be registered in the Quick Memory
Bank.
MEM GROUP
Function: Sets the memory group function.
Available Values: OFF / ON
Default Setting: OFF
Description: Set this setting to "ON" to divide the
memory channels into 6 groups.
QUICK SPLIT INPUT
Function: Input a Quick Split offset frequency.
Available Values: OFF / ON
Default Setting: OFF
Description: When this setting "ON", the Quick
Split offset frequency can be input
from the on-screen keyboard.
QUICK SPLIT FREQ
Function: Selects the amount the frequency is
offset when the Quick Split feature is
enabled.
Available Values: -20 - 0 - 20kHz (1 kHz/step)
Default Setting: 5kHz
• Press and hold the [SPLIT] key to activate
SUB Band split frequency operation, thereby
offsetting the transmitter by the specified fre-
quency.
• Each time the [SPLIT] key is pressed and
held, the frequency offset is increased by the
setting amount.
TX TIME OUT TIMER
Function: Sets the Time-Out Timer countdown time.
Available Values: OFF / 1 - 30 min
Default Setting: OFF
Description: When the time-out timer function
is active, a beep is emitted when a
continuous transmission nears the
set time. About 10 seconds later, the
transceiver is forced to return to the
receiving mode.
98
MIC SCAN
Function: Activates the microphone automatic
scanning function.
Available Values: OFF / ON
Default Setting: ON
Description: Sets the operation of the UP/DWN
keys on the microphone.
ON:
Starts scanning automatically by pressing
and holding the UP/DWN key for 1 second
or more (Scanning continues even after
releasing the button). To stop scanning,
press the UP/DWN key again briefly or
press the PTT button to transmit.
OFF: Scans only while pressing and holding the
UP/DWN key. To stop scanning, release
the button.
MIC SCAN RESUME
Function: Sets the Scan Resume function.
Available Values: PAUSE / TIME
Default Setting: TIME
Description:
PAUSE: During automatic scanning, the scanner
will hold until the signal disappears.
TIME:
If the signal does not disappear within
five seconds, the scanner will resume
scanning for the next active channel
(frequency).
If there are no signals, the scanner con-
tin- ues scanning.
REF FREQ FINE ADJ
Function: Adjusts the reference oscillator.
Available Values: -25 - 0 - 25
Default Setting: 0
Description: The frequency may be calibrated
by connecting a frequency counter
to the transceiver, or by receiving a
standard frequency such as WWV or
WWVH.