  • Page 1 1200 erieS CAT O perATiOn eFerenCe YAESU MUSEN CO., LTD.
  • Page 2 1200 computer before using the SCU-17 USB interface unit. Please see the USB Driver (Virtual COM Port Driver) on the Yaesu Website for details refer to (http://www. yaesu.com/) in the FT 1200 product files section. Note: Do not connect the USB cable and SCU-17 to your personal computer until after the “virtual...
  • Page 3 perATion ompuTer ided rAnsCeiver ontrol ommand A computer control command is composed of an alpha- Parameters betical command, various parameters, and the terminator Parameters are used to specify information necessary to that signals the end of the control command. implement the desired command. Example: Set the VFO-A frequency to 14.250000 MHz.
  • Page 4 perATion ompuTer ided rAnsCeiver Function ommand ommand unCtion VFO-A TO VFO-B PLAY BACK ANTENNA TUNER CONTROL POWER CONTROL AF GAIN SPEECH PROCESSOR LEVEL AUTO INFORMATION SPEECH PROCESSOR VFO-A TO MEMORY CHANNEL POWER SWITCH ANTENNA NUMBER QMB STORE VFO-B TO VFO-A QMB RECALL AUTO NOTCH QUICK SPLIT...
  • Page 5: An Antenna Number

    perATion ompuTer ided rAnsCeiver VFO-A TO VFO-B Read Answer ANTENNA TUNER CONTROL P1 0: Fixed P3 0: Tuner “OFF” P1 P2 P3 P2 0: Fixed 1: Tuner “ON” 2: Tuning Start Read Answer P1 P2 P3 AF GAIN P1 0: Fixed P1 P2 P2 P2 P2 000 - 255 Read...
  • Page 6: Bp Manual Notch

    perATion ompuTer ided rAnsCeiver BREAK-IN P1 0: Break-in “OFF” 1: Break-in “ON” Read Answer MANUAL NOTCH P1 0:Fixed P3 P2=0 P1 P2 P3 P3 P3 P2 0: Manual NOTCH “ON/OFF” 000: OFF 1: Manual NOTCH LEVEL 001: ON Read P2=1 P1 P2 001 - 400 (NOTCH Frequency : x 10 Hz ) Answer...
  • Page 7: Date And Time

    perATion ompuTer ided rAnsCeiver CTCSS P1 0: Fixed P1 P2 P2 0: CTCSS “OFF” 1: CTCSS ENC/DEC “ON” Read 2: CTCSS ENC “ON” Answer P1 P2 able 1 (CtCSS t able hart 67.0 Hz 91.5 Hz 123.0 Hz 162.2 Hz 189.9 Hz 229.1 Hz 69.3 Hz...
  • Page 8 perATion ompuTer ided rAnsCeiver ENCODE P1 0: RTTY P1 P2 1: PSK P2: 1: Message Memory “1” Playback Read 2: Message Memory “2” Playback 3: Message Memory “3” Playback Answer 4: Message Memory “4” Playback  :requires FFT-1 (option) 5: Message Memory “5” Playback ENCORDER UP P1 0: MAIN ENCORDER P1 P2 P2...
  • Page 9 perATion ompuTer ided rAnsCeiver able FunCtion diGitS MODE-CW CW LCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct MODE-CW CW HCUT FREQ 00: OFF 01: 700 Hz ~ 67: 4000 Hz (50 Hz steps) MODE-CW CW HCUT SLOPE 0: 6 dB/oct 1: 18 dB/oct MODE-CW CW AUTO MODE 0: OFF 1: 50 MHz...
  • Page 10 perATion ompuTer ided rAnsCeiver able FunCtion DIGITS SCOPE FIX 28MHz SPAN 02: 20 kHz 03: 50 kHz 04: 100 kHz 05: 200 kHz 06: 500 kHz 07: 1000 kHz SCOPE FIX 50MHz 50.000 MHz ~ 53.999 MHz (P2 = 50000 ~ 53999, 1 kHz steps) SCOPE FIX 50MHzSPAN 02: 20 kHz 03: 50 kHz...
  • Page 11 perATion ompuTer ided rAnsCeiver FAST STEP P1 0: VFO-A FAST Key “OFF” 1: VFO-A FAST Key “ON” 2: VFO-B FAST Key “OFF” 3: VFO-B FAST Key “ON” 4: VFO-A FAST Key “OFF”, VFO-B FAST Key “OFF” Read 5: VFO-A FAST Key “ON”, VFO-B FAST Key “OFF”...
  • Page 12: Mc Memory Channel

    perATion ompuTer ided rAnsCeiver KEYER P1 0: KEYER “OFF” 1: KEYER “ON” Read Answer KEY SPEED P1 004 - 060 (WPM) P1 P1 P1 Read Answer P1 P1 P1 CW KEYING P1 1: Keyer Memory “1” Playback 6: Message Keyer “1” Playback 2: Keyer Memory “2”...
  • Page 13: Nl Noise Blanker Level

    perATion ompuTer ided rAnsCeiver MONITOR LEVEL P1 0: MONI “ON/OFF” P1 P2 P2 P2 1: MONI Level P2 P1=0 Read 000: MONI “OFF” 001: MONI “ON” Answer P1=1 P1 P2 P2 P2 001 - 100 MEMORY CHANNEL READ P1 Memory Channel Number(001 ~ 117) P2 Memory Channel Frequency (Hz) P3 Clarifier Direction +: Plus Shift, -- : Minus Shift Clarifier Offset: 0000 - 9999 (Hz)
  • Page 14: Pb Play Back

    perATion ompuTer ided rAnsCeiver NOISE REDUCTION P1 0: Fixed P1 P2 P2 0: Noise Reduction “OFF” 1: Noise Reduction “ON” Read Answer P1 P2 OPPOSITE BAND INFORMATION P1 Current Memory Channel(001 ~ 117) P2 VFO-B Frequency (Hz) P3 Clarifier Direction +: Plus Shift, -- : Minus Shift Clarifier Offset: 0000 - 9999 (Hz) Read P4 0: RX CLAR “OFF”...
  • Page 15: Rc Clar Clear

    perATion ompuTer ided rAnsCeiver POWER SWITCH P1 0: POWER “OFF” 1: POWER “ON” Read This command requires dummy data be initially sent. Then after one second and before two seconds the command is sent. Answer QMB STORE Read Answer QMB RECALL Read Answer QUICK SPLIT...
  • Page 16 perATion ompuTer ided rAnsCeiver RADIO INFORMATION P1 0: Hi-SWR 8: VFO-B-RX P2 0: OFF 1: MIC-EQ 9: μ-tune 1: ON 3: REC Read 4: PLAY 5: VFO-A TX Answer 6: VFO-B TX P1 P2 7: VFO-A RX NOISE REDUCTION LEVEL P1 0: Fixed P1 P2 P2 P2 01 - 15 Read...
  • Page 17: Sf Sub-Dial Function

    perATion ompuTer ided rAnsCeiver SUB-DIAL FUNCTION P1 1: MHz 2: GRP 3: MCH Read 4: DIAL-B 5: CLAR Answer 6: ---- 7: uTUNE WIDTH P1 0: Fixed P1 P2 P2 P2 00 (See Table 5) Read Answer P1 P2 P2 able ommand andwidth...
  • Page 18 perATion ompuTer ided rAnsCeiver TX SET P1 0: RADIO TX “OFF” CAT TX “OFF” 1: RADIO TX “OFF” CAT TX “ON” 2: RADIO TX “ON” CAT TX “OFF” (Answer) Read Answer PLL UNLOCK STATUS P1 0: PLL “Lock” 1: PLL “Unlock” Read Answer Read...
  • Page 19 perATion ompuTer ided rAnsCeiver TX CLAR P1 0: TX CLAR “OFF” 1: TX CLAR “ON” Read Answer ZERO IN (CW AUTO ZERO IN Function) Read  :requires FFT-1 (option) Answer 1200 CAT Operation Manual...
  • Page 20 Copyright 2013 YAESU MUSEN CO., LTD. All rights reserved No portion of this manual may be reproduced without the permission of 1310-B0 YAESU MUSEN CO., LTD.