23038
Error in the volumetric compensation file: Maximum value exceeded.
DETECTION
On CNC power-up or when validating the machine parameters.
CAUSE
The volumetric definition file does not contain the proper data.
SOLUTION
Set the maximum value of the file as the maximum value in the table.
23039
Error in the volumetric compensation file: Wrong range value.
DETECTION
On CNC power-up or when validating the machine parameters.
CAUSE
The volumetric definition file does not contain the proper data.
SOLUTION
Change the value of the range to the difference between the maximum and minimum
value.
23101
'Error when analyzing the volumetric compensation definition file'
DETECTION
On CNC power-up or when validating the machine parameters.
CAUSE
The volumetric definition file does not contain the proper data.
Basic volumetric compensation:
• The file is not in csv format.
• The format of the file defined in VCOMPFILE is incorrect.
• The file defined in VCOMPFILE does not have all the points defined. The number
of points is defined by the expression:
Medium and large volumetric compensation:
• The format of the file defined in VCOMPFILE is incorrect.
SOLUTION
Select a proper file. The file must be in csv format and have all the points defined in
the basic volumetric compensation.
23101
'Error when analyzing the volumetric compensation definition file'
DETECTION
On CNC power-up or when validating the machine parameters.
CAUSE
The volumetric definition file does not contain the proper data.
SOLUTION
Select a proper file.
23102
'Volumetric compensation system error: Compensation off'
DETECTION
During execution.
CAUSE
The CNC has detected an internal error when calculating the volumetric
compensation and has canceled the compensation values.
SOLUTION
Contact Fagor Automation.
23103
'The VOLCOMP mark cannot be activated without a validated table'
DETECTION
During execution.
CAUSE
The PLC has tried to activate a volumetric compensation that is not defined properly
and therefore the machine cannot be compensated.
SOLUTION
Define a proper volumetric compensation in the machine parameters (VOLCOMP
parameters).
23104
'The VOLCOMP mark cannot be activated while another table is active on common axes'
DETECTION
During execution.
CAUSE
The PLC has tried to activate a volumetric compensation while another one is active
and one of the axes used is common to both compensations.
SOLUTION
There cannot be two active volumetric compensations having an axis in common.
Before activating a compensation, cancel the active one using the corresponding
PLC mark.

23000-23999

NPOINTSAX1 × NPOINTSAX2 × NPOINTSAX3
CNC 8060
CNC 8065
(R
: 1709)
EF
·207·