5000-5999 - Fagor 8065 Error Solving Manual

Hide thumbs Also See for 8065:
Table of Contents

Advertisement

5000
DETECTION
CAUSE
SOLUTION
5001
DETECTION
CAUSE
SOLUTION
5002
DETECTION
CAUSE
SOLUTION
5003
DETECTION
CAUSE
SOLUTION
5004
DETECTION
CAUSE
SOLUTION
5005
DETECTION
CAUSE
SOLUTION
5006
DETECTION
CAUSE
SOLUTION
5007
DETECTION
CAUSE
SOLUTION
5008
DETECTION
CNC 8060
CAUSE
CNC 8065
SOLUTION
5009
DETECTION
(R
: 1709)
CAUSE
EF
SOLUTION
·150·

5000-5999

'PLC error: The timer does not exist'
PLC timer data reading processes.
Request to read a timer that does not exist.
Check the number of the timer; valid timers, T1 to T256.
'PLC error: The counter does not exist'
PLC counter data reading processes.
Request to read a counter that does not exist.
Check the number of the counter; valid counters, T1 to T256.
'CNCRD: Unidentified variable'
When executing a CNCRD instruction.
The variable does not exist. If the error occurs during start-up, the PLC may be trying
to execute a CNCRD instruction before the SERCOSRDY mark is active.
Check the syntax of the variable. If the error occurs during start-up, condition the
reading of the variable to the PLC mark SERCOSRDY being active.
'CNCWR: Unidentified variable'
When executing a CNCWR instruction.
The variable does not exist.
Check the syntax of the variable.
'Variable without reading permission for PLC'
When executing a CNCRD instruction.
Reading of a variable that has no reading permission for the PLC.
Check the permissions of the variable.
'Variable without writing permission for PLC'
When executing a CNCWR instruction.
Writing of a variable that has no writing permission for the PLC.
Check the permissions of the variable.
'Variable writing from the PLC out of range'
When executing a CNCWR instruction.
The value assigned to the variable is not valid.
Check the syntax of the variable and the valid values.
'Syntax error when writing the variable from the PLC'
When executing a CNCWR instruction.
The variable does not exist or it has no permission to be written from the PLC.
Check the syntax and the permissions of the variable.
'The variable could not be written from the PLC'
When executing a CNCWR instruction.
Writing a global or local arithmetic parameter that does not exist.
Check the settings of global and local parameters as well as the PLC program.
'Syntax error when reading the variable from the PLC'
When executing a CNCRD instruction.
The variable does not exist or it has no permission to be read from the PLC.
Check the syntax and the permissions of the variable.
E r r o r so l v i n g m a n u a l .

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8060

Table of Contents