4000-4999 - Fagor 8065 Error Solving Manual

Hide thumbs Also See for 8065:
Table of Contents

Advertisement

4000(1)
CLASS
CAUSE
SOLUTION
4000(2)
CLASS
TRANSITION
CAUSE
SOLUTION
4000(3)
AXIS
TRANSITION 1
TRANSITION 2
CNC 8060
CNC 8065
(R
: 1709)
EF
·140·

4000-4999

'Error when initializing the Sercos ring'
0.
Error when initializing the chip. The CNC does not detect the Sercos board or overflow
at the DPRAM of the SERCON due to too many axes and data to be transmitted in
the cyclic channel.
Verify that the board is installed and that the CNC detects it correctly. If the error
persists, contact the Service Department.
'Error when initializing the Sercos ring'
1.
0.
Timeout when requesting Sercos ring initialization.
Contact our technical service department.
'Error when initializing the Sercos ring'
Name of the axis issuing the error.
Sercos ID that causes the error. Refer to the drive manual.
Point of the initializing sequence where the error occurs.
Point.
Meaning.
0
Timeout.
1
Error when changing to Phase 0.
(Trouble at the optical fiber)
2
Error when changing to Phase 1.
(A drive does not respond; hardware failure or node selector set wrong)
3
Error when changing to Phase 2.
4
Error when reading the OEM version.
5
Error when reading T1min.
6
Error when reading Tatmt.
7
Error when reading T4min.
8
Error when reading Tmtsy.
9
Error when reading Tmtsc.
10
Error when reading SlaveNr.
11
Error when reading Tatat.
12
Error when calculating times.
13
Error when writing the OEM Password.
14
Error when writing T1.
15
Error when writing T4.
16
Error when writing T3.
17
Error when writing T2.
18
Error when writing Tncyc.
19
Error when writing Tscyc.
20
Error when writing MDTlen.
21
Error when writing TelegramType.
22
Error when writing MDT List.
23
Error when writing AT List.
E r r o r so l v i n g m a n u a l .