8.7 Self Cleaning Filter

1. From pump
2. To safety valve
3. Filter housing cover
4. To operating unit
5. Return line/
constant agitation
6. Filter housing cover nut
Fig. 35
This filter automatically flushes out particles and chemical deposits,
reducing routine maintenance, nozzle plugging and operator exposure.
No adjustments are required but different mesh screens may be installed
for various types of products. A good practice is having the necessary new
O-rings on hand at the time of changing screens or when performing
routine maintenance. O-ring part numbers are #242020, #241953,
#242047.
Note: It is advisable to have the sprayer tank empty before carrying
out any maintenance on the self-cleaning filter.
To clean or replace filter, loosen nut (6) (Fig.35) to remove filter housing
cover (3) (Fig.35) lift filter screen out. Replace screen and filter housing
cover. Press down on cover (3) (Fig.35) and turn the cover nut (6) (Fig.35)
clockwise until snug.