Installation Procedure - Huawei OptiX OSN 3500 Quick Installation Manual

Hide thumbs Also See for OptiX OSN 3500:
Table of Contents

Advertisement

b
Cable Connections
c

Installation Procedure

1
1
Install the mounting ears.
NOTE
When you install the SS62COA inside the cabinet, 125 mm of space is required.
NOTE
When being installed above or below the subrack, the SS62COA does not require a slot in the subrack.
By default, the SS62COA is installed in the lowest part of the cabinet (namely, in the positions of the first and
third floating nuts) and is more than 50 mm away from the subrack.
The SS62COA can be installed in a cabinet that is not fully configured with subracks, but future expansion will be
affected due to reduced installation space in the cabinet.
A
To the power supply facilities in the
telecommunications room
Phillips screwdriver
M4
12±1.2 Kgf.cm
2
19
A
To the serial port of the
SS62COA
Serial port cable
2
Secure the SS62COA on the columns.
M6
30±3 Kgf.cm