Huawei OptiX OSN 3500 Quick Installation Manual page 76

Hide thumbs Also See for OptiX OSN 3500:
Table of Contents

Advertisement

Name
Content
Engineering
labels for the
MN-B-C-D-R/T
trunk cables
between two
pieces of
equipment
Engineering
labels for the
trunk cables
DDF-MN-BC-D/R/T
between the
equipment and
the DDF
MN-B-C-D-R/T
Labels for
optical fibers
from the
equipment to
the ODF
ODF-MN-B-CR/T
Example
G01 01
05
12
T
G01-01-05-12-T: indicates that the
local end of the trunk cable is
connected to the optical transmit
port of trunk cable 12 in slot 05 of
subrack 01 in the cabinet in row G
and column 01 in the
telecommunications room.
A01
03
01
01
R
DDF-G01-01-01-AR: indicates that
the opposite end of the trunk cable is
connected to the optical receive port
of the terminal in direction A (for
connection to the optical network
equipment) in row 01 and column 01
on the DDF in row G and column 01
in the telecommunications room.
ODF G01 01
01
R
ODF-G01-01-01-R: indicates that the
local end of the optical fiber is connected
to the optical receive port on the terminal
in row 01 and column 01 of the ODF in
row G and column 01 in the
telecommunications room.
A01-01-05-05-R: indicates that the
opposite end of the optical fiber is
connected to optical receive port 05 in
slot 05 of subrack 01 in the cabinet in row
A and column 01 in the
telecommunications room.
73
Remarks
MN: cabinet number
B: subrack number
C: physical slot number
D: cable number
R: optical receive port
T: optical transmit port
MN: row number and column
number of the DDF
B: row number of the terminal
C: column number of the terminal
D: direction A or B
R: optical receive port
T: optical transmit port
MN: cabinet number
B: subrack number
C: physical slot number
D: network port number
R: optical receive port
T: optical transmit port
MN: row number and column
number of the ODF
B: row number of the terminal
C: column number of the terminal

Hide quick links: