Framing And Clearances; Appliance/Decorative Finish Dimension Diagrams - HEAT GLO PRIMO48 Installation Manual

Hide thumbs Also See for PRIMO48:
Table of Contents

Advertisement

3

Framing and Clearances

A. Appliance/Decorative Finish Dimension Diagrams
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3.B.
PowerFlow™ Heat Management Systems Seal Plates
IMPORTANT: Must use appropriate seal plate(s) for
the selected PowerFlow™ Heat Management system.
See Section 6.
A
B
Location
* = Mimimum Vent Height (using SLP90)
Figure 3.1 Appliance Dimensions - PRIMO48, PRIMO60, PRIMO72
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. Z • 3/19
Q
GAS
ACCESS
V
F
E
G
D
H
C
PRIMO48
Inches
Millimeters
A
41-3/4
1060
B
2-5/16
59
C
7-11/16
195
D
2-13/16
71
E
4
102
F
23-13/16
605
G
8-1/4
210
H
3-1/2
89
I
51-1/16
1297
J
60-15/16
1548
K
13-3/8
340
L
9-3/8
238
M
39-1/2
1003
N
2-1/16
52
O
37
940
P*
44-3/4
1137
Q
17-3/16
437
R
59-1/2
1511
S
8-5/8
219
T
18-3/16
462
U
8
203
V
30-9/16
776
R
o
U
CENTERED ON APPLIANCE
ELECTRICAL ACCESS
I
J
PRIMO60
Inches
Millimeters
47-3/4
1213
2-5/16
59
7-11/16
195
2-13/16
71
4
102
23-13/16
605
8-1/4
210
3-7/16
87
63-1/16
1602
72-15/16
1853
13-3/8
340
9-3/8
238
39-1/2
1003
2-1/16
52
37
940
44-3/4
1137
17-3/16
437
71-1/2
1816
8-5/8
219
18-1/8
460
8
203
30-9/16
776
T
S
M
K
L
PRIMO72
Inches
Millimeters
47-3/4
1213
2-5/16
59
7-11/16
195
2-13/16
71
4
102
23-13/16
605
8-1/4
210
3-7/16
87
75-1/16
1907
84-15/16
2157
13-3/8
340
9-3/8
238
39-1/2
1003
2-1/16
52
37
940
44-3/4
1137
17-3/16
437
83-1/2
2121
8-5/8
219
18-1/8
460
8
203
30-9/16
776
P
O
N
9