B. Vent Collar Preparation
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during
installation. Sheet metal edges are sharp.
The PRIMO is shipped standard with an attached DVP
pipe section. Do not remove. When SLP pipe will be
used for venting, the included DVP-2SL adaptor can be
used to make the conversion from DVP pipe to SLP pipe.
1. Place the 1/8 inch thick, square pipe gasket over the
initial six inch vent section.
2. Secure square pipe gasket with four screws.
3. Remove DVP seal cap. Attach the included DVP-2SL
to the vent system with the two screws.
Note: The DVP-2SL may be installed at any point within
the appliance venting system.
Note: DO NOT remove installed DVP pipe section. Use
DVP-2SL to convert for use with SLP pipe.
WARNING! Risk of Fire! DO NOT remove
PowerFlow™ Heat Management seal plate unless
a PowerFlow™ Heat Management System will be
connected at that location. Overheating of appliance
and combustible materials will occur.
Figure 6.3 Vent Collar Preparation
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. Z • 3/19
PASSIVE HEAT SEAL PLATE OR
HEAT-ZONE SEAL PLATE
HEAT-OUT SEAL PLATE*
SEAL CAP
DVP PIPE ATTACHED
SQUARE PIPE GASKET
HEAT-OUT SEAL PLATE*
4. A minimum of one PowerFlow™ Heat Management
System is required. Select required PowerFlow™
Heat Management System(s) and remove the appro-
priate seal plate(s) as indicated in Figure 6.3. See
Section 6.C for more information.
• Heat Zones (HEAT-ZONE-PRIMO)
Quantity 2 included in kit
• Passive Heat- 2 Options:
1. PHFR-PRIMO-48 / PHFR-PRIMO-60
(Front Discharge) Quantity 2 plenums per kit
Trim kit required; order separately
2. PHSI-PRIMO (Side or Open Top Discharge)
Quantity 2 registers included in kit
• Heat Out (HEAT-OUT-PRIMO)
Remove only one of the two seal plates if installing the
HEAT-OUT-PRIMO. The other HEAT-OUT-PRIMO plate
must remain in the factory-installed position.
WARNING! Risk of Overheating! Remove only one
seal plate to install HEAT-OUT-PRIMO. Overheating of
appliance and combustible materials will occur.
6-3/8 in.
163 mm
4 in.
102 mm
8-1/8 in.
206 mm
HEAT-ZONE SEAL PLATE OR
PASSIVE HEAT SEAL PLATE
*
Note: Remove only one of the two middle seal plates if
installing the HEAT-OUT-PRIMO. The other plate must
remain installed.
4-3/16 in.
106 mm
4-5/8 in.
117 mm
5-1/16 in.
128 mm
DVP-2SL
Adapter (Included)
29