G. Power Vent Baffle Adjustment
PVI-SLP-B Baffle Adjustment
The PVI-SLP-B has a baffle adjustment which must
remain set in the closed position. This baffle adjustment
is located alongside the motor. The baffle adjustment
is measured using the holes on the indicator bar of the
PVI-SLP-B baffle. This bar raises as the baffle is opened
and lowers as the baffle is closed. When only one hole is
showing, the baffle is closed. The PRIMO requires that
the baffle MUST remain set in the CLOSED position as
indicated in Figure 4.6.
For more information regarding installation of the PVI-
SLP-B, refer to the instruction included with that acces-
sory.
CAUTION! Risk of Overheating! Set and secure baffle
indicator as instructed. Overheating could occur causing
appliance to shut down.
PRIMO48/PRIMO48ST (NG) Only:
Baffle Setting Exception: Due to the tendency of air to
move more quickly through the power vent in a smaller
size appliance, the PRIMO48/PRIMO48ST may require
a "two-hole" setting instead of being closed. If the pilot is
unstable, adjust the baffle. See the PVI-SLP-B installa-
tion instructions for baffle adjustment information.
Figure 4.6 PVI-SLP-B Baffle Indicator
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. Z • 3/19
24
24
24
INDICATOR BAR
PVLP-SLP Baffle Adjustment
The PVLP-SLP baffle is closed when the locking screw
remains installed. The PRIMO requires that the baffle
MUST remain in the CLOSED position as indicated in
Figure 4.7.
For more information regarding installation of the PVLP-
SLP, refer to the instruction included with that accessory.
PRIMO48/PRIMO48ST (NG) Only:
Baffle Setting Exception: Due to the tendency of air to
move more quickly through the power vent in a smaller
size appliance, the PVLP-SLP baffle may need to be
opened up no more than 1/2 inch on the PRIMO48 and
PRIMO48ST. If the pilot is unstable, adjust the baffle.
See the PVI-SLP-B installation instructions for baffle ad-
justment information.
CAUTION! Risk of Overheating! DO NOT remove the
locking screw on the baffle. Appliance could overheat.
DO NOT REMOVE THIS SCREW
DO NOT REMOVE THIS SCREW
Figure 4.7 PVLP-SLP Baffle Locking Screw