Wiring Requirements - HEAT GLO PRIMO48 Installation Manual

Hide thumbs Also See for PRIMO48:
Table of Contents

Advertisement

B. Wiring Requirements
IntelliFire
Plus Ignition System Wiring
TM
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.7, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire™ Plus
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the appliance.
JUNCTION BOX
110-120 VAC
2005-021
WIRE PLUG ASSEMBLY
(Female Connectors
Included)
Figure 8.7 PRIMO Wiring Diagram
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. Z • 3/19
42
42
42
2155-755
2310-211
2273-308
(PRIMO72ST ONLY)
2273-308
2310-211
2310-204
THERMODISC
2196-150
PVI MODULE
2196-200 PVI-WIRE HARNESS
RED
2179-300
107-558A MALE/FEMALE
BLK
BLK
WIRE HARNESS
6V TRANSFORMER
2159-310
2206-298
RESET SWITCH
Thick line denotes wiring
supplied by electrician.
2155-204
LED SWITCH
2155-752
2310-200
SEE THROUGH ONLY
2166-335 AUX
PVI-WHXX
GRN
(TO VALVE)
GROUND
ORG
BROWN
2310-202
THERMODISC
PVI-SLP OR PVLP-SLP REQUIRED
PVLP-SLP
2300-753 JUMPER WIRE
LED'S
2310-062
BLUE
2155-033
RED
JUMPER WIRE
BROWN
PVI-SLP
RC300 4.5V DC
(AAA X 3)
HEAT-ZONE-PRIMO
HEAT-OUT-PRIMO

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primo48stPrimo60Primo60stPrimo72Primo72st

Table of Contents