Safety Instructions; Operator Precautions; Environmental Considerations; Declaration Of Safety Conformity And Ce Marking - ABB PowerValue 31/11 T 10 kVA User Manual

Table of Contents

Advertisement

1 SAFETY INSTRUCTIONS

1.1

Operator precautions

The user must follow the precautions and only perform the described operations. Also in these
measures, the operator of the UPS System must adhere to the instructions in this manual. Any
deviations from the instructions could be dangerous to the user or cause accidental load loss.
The only user operations permitted are:
- Use of the LCD control panel (LCD Display) and Maintenance Bypass (if present)
- Start up and shut down of the UPS (excluding the commissioning start up)
- Operation of additional connectivity devices
THE SUPPLIER DOES NOT TAKE ANY RESPONSIBILITY FOR DAMAGES CAUSED THROUGH
WRONG MANIPULATIONS OF THE UPS SYSTEM.
WARNING!
WARNING!
WARNING!
1.2

Environmental Considerations

To operate the UPS at the best efficiency point, your installation site should meet the environmental
parameters outlined in this manual. Excessive amount of dust or moisture in the operating environment
may cause damage or lead to malfunction. The UPS should be always protected from the outside
weather and sunshine. The operating environment must meet the weight, airflow, size and clearance
requirements specified in the technical datasheet.
Under no circumstances, the UPS should be installed in an airtight room, in the presence of flammable
gases, or in an environment exceeding environmental requirements here below.
An ambient temperature of +20°C to +25°C is recommended to achieve a long life of the UPS and
batteries. The cooling air entering the UPS must not exceed +40 °C and the humidity should be below
95% (non-condensing).
1.3

Declaration of Safety conformity and CE marking

PowerValue 31/11 T is designed, manufactured and commercialized in accordance with the standard
EN ISO 9001 of Quality Management Systems. The marking shows the conformity to the EEC Directive
by means of the application of the following standards in accordance with the specifications of the
harmonized standards:
• 2006/95/EC Low voltage directive.
• 2004/108/EC Electromagnetic Compatibility directive (EMC).
IT IS PROHIBITED TO REMOVE ANY SCREWS FROM THE UPS
SYSTEM OR FROM THE BATTERY CABINET: DANGER OF
ELECTRICAL SHOCK.
HIGH
FAULT
BEFORE CONNECTING THE MAINS YOU MUST ENSURE THAT
THERE IS A PROPER EARTH CONNECTION!
THE USER MUST DISPLAY A WARNING SHIELD ON ALL PRIMARY
UPS CIRCUIT BREAKERS. THE SERVICE PERSONNEL HAS TO BE
INFORMED ABOUT DANGEROUS VOLTAGES. THE WARNING
PANELS MUST CONTAIN THE FOLLOWING TEXT: "BEFORE
STARTING WITH THE MAINTENANCE WORK ON THE CIRCUIT
BREAKERS, MAKE SURE THE UPS IS ISOLATED."
4NWP100559R0001_OPM_ABB_PVA31-11-T_10-20kVA_EN_140626
Modifications reserved
CURRENTS
(LEAKAGE
CURRENTS):
Page 6/37 ABB