Operation
5.2.5

Display Sequence

D000027979 en t – E350 Series 2, 3-Phase ZxF100Ax/Cx – User Manual
The previous section showed in detail the possible displays. The display
sequences shown on any specific customer's product are set through
parameterisation at the factory.
There are two display sequences:
Main display (with an auto-scroll list and a recall list)
Service display (with the service list)
The main display can include up to 31 displays, the service display up to 63
displays (defined by parameterisation).
The parameters which have an influence on the display sequence must be
defined in the configuration process.
These items are:
Leading zeros can be enabled/disabled for registers
Energy register displays can be defined with an integer part of 6 digits
(in exceptional cases 5) and with 0, 1, 2 or 3 decimal places. Max. 6
significant digits (left of the decimal point) are allowed. Max. 8 digits
including decimal places are available.
Only 6 integer digits are allowed for meters according to MID.
Active rate indication can be enabled or disabled
Flashing decimal point in the energy register displays to indicate that
the meter is in the service or certification display sequence
Main display
Auto scrolling list
Value 1
Value 2
Value n
Recall list
Consumption since reset
Value 2
Value 3
Value x
= short press of display button (< 5 s)
Fig. 5.4 Overview display sequences
Meter start
Service display
(power up)
Service list
Reset of
register
= long press of display button (> 5 s)
35/56
Value 1
Value 2
Value 3
Value 4
Value 5
Value 6
Value y