Display Format; Digital Power Indicator; Power Up Display Sequence - Landis+Gyr FOCUS KWH Technical Manual

Solid-state meter
Table of Contents

Advertisement

The segment check display does not affect the DPI. This permits a user to use the DPI for timing when
a segment check is being displayed during a scroll sequence.
A two character programmable alphanumeric label can be associated with each display. This two-
character field is used to identify the value displayed. It can be left blank if desired.
5.1.3.

Display Format

The display accommodates the following digit formats:
6x1
5x1
4x1
4x10 (Four digit display with the least significant digit representing 10kWh per increment)
The energy display format is programmable at the factory or by the user with
Display format does not affect the segment check, meter error codes or line voltage readings.
5.1.4.

Digital Power Indicator

The Focus kWh has a digital power indicator similar to the Landis+Gyr traditional "caterpillar" and
consists of six segments.
The DPI moves from left to right at a rate proportional to energy delivered to the load and moves from
right to left at a rate proportional to the energy received from the load.
The DPI makes one revolution for each Kh of metered energy.
Each DPI segment on/off transition is observable when occurring at a maximum rate of one on/off
transition each .45 second at –20ºC and above.
5.1.5.

Power Up Display Sequence

All Focus kWh display segments, including the DPI segments, illuminate after the meter is powered up
regardless of the display sequence program. This segment check display persists for less than five
seconds upon meter power-up, after which time the display begins its programmed scroll sequence.
14
14
Focus Configuration Tool.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents