Extron electronics DTP T DSW 4K Series User Manual page 12

Hide thumbs Also See for DTP T DSW 4K Series:
Table of Contents

Advertisement

D
DTP/HDBaseT output — Use an STP cable to connect this output to the input of a
compatible receiver (see
on page 8 for more information).
ATTENTION:
Do not connect these ports to a computer data network or a
telecommunications network.
Veuillez ne pas connecter ces ports à un réseau de données informatiques ou
à un réseau de télécommunications.
Do NOT connect an HDBaseT unit if using DTP transmission. The power
carried over DTP may damage the unit.
Ne PAS connecter une unité HDBaseT si vous utilisez la transmission DTP.
L'alimentation transmise sur DTP peut endommager l'unité.
Remote power is intended for indoors use only. No part of a network that uses
remote power can be routed outdoors.
L'alimentation à distance est exclusivement réservée à un usage en intérieur.
Un réseau utilisant une alimentation à distance ne peut pas être routé en
extérieur.
E
DTP/HDBaseT configuration switch — Set this 2-position, recessed switch to
configure the output between DTP and HDBaseT modes. When configured for DTP, use
a DTP-compatible receiver. When configured for HDBaseT, use an HDBaseT-compatible
receiver.
NOTES:
When the switch is set to DTP mode and the unit is locally powered, the
DTP T DSW 4K units can provide remote power to a compatible receiver. The
units cannot receive remote power in either mode.
When the switch is set to HDBaseT mode, remote power is disabled and
power supplies are required for both switcher and receiver. Analog audio is
enabled, but incompatible with third-party HDBaseT devices.
F
Over TP port
RS‑232 Over TP port — To pass bidirectional serial control between
DTP-compatible or HDBaseT-compatible devices, connect a control
device to the 5-pole captive screw connector. This port includes only the
3 poles labeled "RS-232" (see image below for wiring instructions).
IR Over TP port — To transmit and receive IR signals, connect a
control device to the 5-pole captive screw connector. This port includes
only the 2 poles labeled "IR" and shares the ground pole with the RS-
232 port (see figure 4 for wiring instructions).
Tx/Rx
Pins
Figure 4.
Over TP Port Wiring
NOTE: RS-232 and IR data can be transmitted simultaneously.
Twisted Pair Recommendations for DTP Communication
IR Device
Rx
Tx
Gnd
Tx
Rx
Gnd
RS-232 Device
Extron DTP T DSW 4K Series • Installation and Operation
RS-232
IR
Tx Rx G
Tx Rx
RS-232
IR
Tx Rx G
Tx Rx
6