Replacing the Main Battery Pack

Periodically you must replace the main battery pack.
Figure 5-5. Main Battery Pack
The device provides a battery cable with two pairs of battery connectors, enabling you to hot-swap
the battery pack in a non-hazardous location. You attach the new battery pack to the free
connector (leaving the old one connected), and then disconnect the old battery pack.
Service and Troubleshooting
To replace the HMI module, line up the printed circuit board (PCB) with the slot on the back
and gently press it back on. Tighten the four captive fastening screws.
Close the enclosure.