Replacing The Main Battery Pack - Emerson FB1100 Instruction Manual

Flow computer
Hide thumbs Also See for FB1100:
Table of Contents

Advertisement

FB1100 Flow Computer Instruction Manual
D301752X012
November 2023
4.
5.
6.
4.5

Replacing the Main Battery Pack

Periodically you must replace the main battery pack. FBxConnect provides a battery life
indicator to show the number of days in use. In addition, if you use a lithium battery for
main power, the Status LED shows yellow when the battery is low and needs to be
replaced.
If lead acid battery voltage falls below 4.7V, the battery can no longer be recharged, and
the charging system considers the battery dead. You must replace the battery.
58
Figure 4-3. Captive Fastening Screws
Grasp the HMI module and remove it by gently pulling it straight out away from the
unit.
To replace the HMI module, line up the printed circuit board (PCB) with the slot on
the back and gently press it back on. Tighten the four captive fastening screws.
Replace the end cap. Screw the end cap clockwise (eight full turns) until it is tightly
sealed to the enclosure. Re-attach the retaining clamp, if applicable (see
2.6.1).
WARNING
Section
Service and Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents