Replacing the Main Battery Pack

Periodically you must replace the main battery pack. FBxConnect provides a battery life indicator
showing the number of days of usage to help you monitor battery life. In addition, for lithium
batteries only, the Status LED shows yellow when the battery is low and needs to be replaced.
The device provides two battery connectors, enabling you to hot-swap the battery pack in a non-
hazardous location. Slide out the first battery pack (leaving it connected), attach the new battery
to the second (available) connector (so both batteries are connected), and then disconnect the old
battery pack.
DANGER
EXPLOSION HAZARD: Do not replace batteries unless power has been switched off or the area is
known to be non-hazardous. Batteries must only be changed in an area known to be non-
hazardous.
WARNING!
There are no user-serviceable parts inside the battery pack. Do not open the battery pack as you
may damage the battery pack or injure yourself.
Note
These cells are to be used only in devices where servicing of the cell circuit and replacement of the
lithium cells will be done by a trained technician.
Keep the replacement battery pack handy during the procedure.
1.