Pole Mounting - Aluminum Enclosure - Emerson FB2100 Instruction Manual

Flow computer
Hide thumbs Also See for FB2100:
Table of Contents

Advertisement

Figure 2-14. O-rings with Flange Adapters
1
2
3
4
1.
2.
3.
Pole Mounting – Aluminum Enclosure
Refer to
1.
2.
3.
4.
Installation
Flange
O-ring
Square PTFE-based profile
Round Elastomer profile
Whenever the flange or adapters are removed, visually inspect the O-rings.
Replace the O-rings if there are any signs of damage, such as nicks or cuts.
If the O-rings are replaced, re-torque the flange bolts and alignment screws after installation
to compensate for seating of the O-rings.
Figure 2-15
during the mounting procedure.
Apply Loctite
®
222 Low Strength Purple Threadlocker sparingly to threads of head cap
screws (Item 2).
Attach pole mounting brackets (Item3) to enclosure using head cap screws (Item 2) and hex
nuts (Item 1). Torque hex nuts to 30 in-lbs (3.4 N m).
Apply Loctite 222 Threadlocker sparingly to threads of U-bolts (Item 4).
Use U-bolts (Item 4) to mount enclosure to pole using hex nuts (Item 1). Torque hex nuts to
30 in-lbs (3.4 N m).