MENU 8.7 – SETUP NUMBER & SETTINGS
SETUP (D.A.N. 8711) Setup Number
Quick entry value to select weigh method (1-4 lb) (5-8 kg), gain (1-9), display counts (0-9), and capacity
(*1000)
Display Count Setting Recommendation
Recommended display count setting equals capacity divided by 4,000. Example: System has capacity of 40,000 lb.
Display count code should be "6" or more (10 lb/count or greater).
Capacity Setting Recommendation
Capacity should be set as low as possible but must be set higher than the maximum safe gross load expected on
the system.