W MTHD (D.A.N. 1005) Weigh Method
Weigh method allows the operator to adjust how much processing or number-crunching the scale processor does to
the load cell data before displaying the weight.
1 – General 2 – Slow 3 – Fast 4 – "Lock-on" (animal weighing, available only in Stock Weigh models)
1 ZERO (D.A.N. 1006) One Touch Zero
When enabled, allows the user to press and hold the ZERO key for 3 seconds to balance the scale. Normal balance
procedure is a 2-button operation, it is performed by pressing the NET/GROSS key and then the ZERO key within 3
seconds.
AUTOFF (D.A.N. 1007) Auto Off
This feature allows the operator to have the indicator automatically shut itself OFF after 15, 30, 45 or 60 minutes of
inactivity. This feature will extend battery life on battery powered portable scales and equipment like seed tenders
which use their own power supply or battery. Prior to the scale shutting off, the message "GOODBYE" will be
scrolled across the display for approximately 15 seconds. Pressing a key on the indicator during this time will
prevent the unit from turning off and restart the internal shut-off timer. A jumper on the main board is typically
required for this function to operate.
LB-KG (D.A.N. 1008) Display Unit
Select desired weight unit to be displayed. When changing weight unit using the long form, the calibration is
adjusted so the scale displays accurately in the new display unit.
WT COM (D.A.N. 1009) Weight Compensation
Enables weight compensation functionality.
PREFLT (D.A.N. 1011) Pre-Filtering
Enables pre-filtering before W MTHD is applied
MENU 1.1 – GENERAL SETTINGS (JUMP LIST 11)
SCROLL (D.A.N. 1101) Scroll Delay
This Scroll Rate setting allows the operator to slow down how fast messages scroll across the display when
temperatures drop down below 20° F (-7 C). The selection ranges from "0" (fast) to "9" (slowest). The default setting
is "4".
SAVTAR (D.A.N. 1102) Save Tare
Saves the Tare weight into Non-Volatile Memory and is remembered even after the unit has been turned off. This allows the Net
weight to be restored once the unit has been turned ON again. This feature is available on single and multiple platform (A/B/C)
scale systems
PRETAR (D.A.N. 1103) Pre-Tare
The PRETAR feature allows the tare weight of a container to be entered using the numeric keypad.
PWRLOS (D.A.N. 1104) Power Loss Message
ON = stores time/date of power loss and displays data when power is restored.