Digistar SCALE LINK SL2 Technical Manual page 53

Table of Contents

Advertisement

CAP (D.A.N. 7206) CAPCITY
Enter MAXIMUM weight measurable on scale.
WMA1-1 (D.A.N. 7207) WM1 ADJUST 1
Increase this number to smoothen weighing (2 to 100)
WMA1-2 (D.A.N. 7208) WM1 ADJUST 2
0=OFF. Use value less than WMA1-1 for quick weight response.
WMA1-3 (D.A.N. 7209) WM1 ADJUST 3
Enter the weight to activate quick weight response.
WMA2-1 (D.A.N. 7211) WM2 ADJUST 1
Increase this number to smoothen weighing.
WMA2-2 (D.A.N. 7212) WM2 ADJUST 2
0=OFF. Use value less than WMA2-1 for quick weight response.
WMA2-3 (D.A.N. 7213) WM2 ADJUST 3
Enter the weight to activate quick weight response.
MOTION (D.A.N. 7214) MOTION
ON = motion arrow flashes for unstable weight.
MOT WT (D.A.N. 7215) MOTION WEIGHT
Enter weight used to detect Motion. 0=Standard Motion detection.
TAREAP (D.A.N. 7216) TARE AUTO PRINT
ON = tare will auto-print displayed weight.
SAVTAR (D.A.N. 7217) SAVE TARE
ON = Indicator will save tare weight to non-volatile memory.
WT COM (D.A.N. 7218) WEIGHT COMPENSATION
Enables weight compensation functionality for scale platform A
AD FLT (D.A.N. 7219) AD FFT FILTERING
Enables A/D FFT filtering for scale platform A
CAL100 (D.A.N. 7221) FRACTIONAL WEIGHT CALIBRATION
Enables use of fractional CAL numbers for scale platform A
GAIN (D.A.N. 7222) GAIN
Select gain setting to be used for scale platform. (.75mv/v, 1.5mv/v, 3mv/v)