Digistar SCALE LINK SL2 Technical Manual page 35

Table of Contents

Advertisement

" 142-5" - Normal weight decimal value also showing motion is active.
2
Transmit weight displayed 2 times per second.
Same data format as setting 1
3
Transmit weight displayed 3 times per second.
Same data format as setting 1
4
Transmit weight displayed 10 times per second.
Same data format as setting 1
5
Transmit weight displayed using the Display Rate setting (D RATE D.A.N. 1002).
Same data format as setting 1
6
Transmit weight display whenever the displayed weight changes to a different value.
Same data format as setting 1
7
Transmit comma delimited data which includes the basic weighing information 1 time per second.
Output example:
1234567890123456789012345678901234567890
"
280,LB,GR,
8
Transmit comma delimited data which includes the basic weighing information once every 5
seconds.
9
Selection #9 is reserved.
11
Transmit comma delimited data which includes the "serial gross weight" 2x/second.
D4204-EN
Includes Gross Weight, display unit, weight tag (GR, M+, etc...), Total Rotation Count, Date &
Time with seconds.
Ends with a <CR>,<LF>. (Carriage Return, Line Feed) PA
1
2
187,03JL03, 3:41:21"
Same data format as setting 7
Scale Link 2 Technical Manual
3
4
35

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Digistar SCALE LINK SL2

This manual is also suitable for:

Sl2110Sl2140Sl2210Slc2810Sl2220

Table of Contents