Installed power
Net mass
Net mass
Air quality (Pharmacopeia)
O
concentration
2
CO
concentration
2
CO concentration
SO
concentration
2
NO
concentration
x
Pressure dew point
Pressure dew point
Oil vapour
Taste and odour
Data at 10 bar inlet pressure
Volume flow at dryer inlet
Volume flow at dryer inlet
Pressure drop over dryer
Pressure drop over dryer
Time of half a cycle
Regeneration time
Pressurization time
Regeneration air consumption (average) %
Installed power
Net mass
Net mass
Amount of desiccant per vessel (CD)
Amount of desiccant per vessel(CD)
Amount of activated carbon per vessel
(QDT)
Amount of activated carbon per vessel
(QDT)
Air quality (Pharmacopeia)
O
concentration
2
CO
concentration
2
CO concentration
SO
concentration
2
2920 7099 70
Unit
dMED 70 dMED 80 dMED 100
VA
124
kg
219
lb
483
%
ppm
ppm
ppm
ppm
°C
°F
mg/m³
Unit
dMED 7
dMED 13 dMED 25 dMED 35 dMED 50
l/s
8.4
15.6
cfm
14.8
27.5
mbar
515
530
psi
7.47
7.69
s
180
180
s
145
145
s
35
35
15.8
15.8
VA
63
63
kg
246
265
lb
542
584
kg
8.2
8.2
lb
18.1
18.1
kg
2.0
2.0
lb
4.4
4.4
%
ppm
ppm
ppm
124
124
239
267
527
589
20.4<X<21.
4
≤ 500
≤ 5
≤ 1
≤ 2
≤ -31
≤ -23.8
≤ 0.1
free
30
42
53.0
74.2
560
595
8.12
8.63
120
120
95
95
25
25
15
15
63
82
305
344
672
758
8.2
11.6
18.1
25.6
3.8
3.8
8.4
8.4
20.4<X<
21.4
≤ 500
≤ 5
≤ 1
dMED 145
166
354
780
60
105.9
820
11.89
120
95
25
15.8
82
389
858
15.3
33.7
4.8
10.6
83