BeaconMedaes dMED 7 Instruction Book page 52

Dual medical air purifiers
Table of Contents

Advertisement

(1)
Activate service
(2)
Dryer 1
(3)
Dryer 2
• Depressurize vessels
To ensure the dryer is fully depressurized before performing any maintenance, this function will activate
all exhaust solenoids of the dryer in service mode for the preset time to blow off remaining air still present
in the dryer. Always check the pressure gauges before performing any maintenance.
(1)
Depressurize vessels
(2)
Remaining time
• Drying after service
Whenever a dryer has been serviced receiving new desiccant, it is possible this desiccant is not able to
reach a good dew point right away. Therefore, the drying after service function should be activated. This
function uses dried air from the active dryer to ensure the desiccant of the backup dryer will be in optimal
condition when switch-over is required. This function will be disabled automatically after a preset time.
50
(4)
Remaining time
(5)
Activate
(6)
Modify
(3)
Activate
Instruction book
2920 7099 70

Hide quick links:

Advertisement

Table of Contents
loading