BeaconMedaes dMED 7 Instruction Book page 31

Dual medical air purifiers
Table of Contents

Advertisement

Instruction book
Testing the alarms
Before starting the plant, the alarms can be tested. The 4 alarms will automatically cycle for 3 seconds without
actual faults. This can be used to test the transmission to the control room alarm display. Navigate to the
following submenu and press the Enter button:
When the test icon is greyed out, the plant needs to be stopped first. Refer to the paragraph Stopping to stop
the ES-MED.
Starting the ES-MED
To start the system, after having completed the CAN and ES setup described above, carry out the following
steps:
1. Put the compressor's main switch to ON and the local/LAN switch to LAN. The emergency forced local
warning (see section
is on, since the pressure is lower than the preset emergency pressure level.
Once the pressure is above this level (on the display of the compressor controller), press the escape button
on the compressor controller. The warning disappears and the red LED extinguishes.
2. Then carry on to start the ES system (full access mode, see above).