Landis+Gyr
3. Type iscellnet.
If the ping is successful, the system returns the length of time it took to receive a response. If the
ping is unsuccessful, the system indicates a time out condition.
Hot-Booting a Concentrator
Always perform a disconnect, followed by a hot boot, before any download operations. For a
firmware upgrade to be successful, it must load on top of system variables set to their default values.
If you always perform a hot reboot, you always start with default values.
1. Open a command window on your PC.
2. Use your administrative credentials to login as control user.
3. Type mcc_cmd 30000.1 -resethot.
Concentrator User and Installation Guide
Figure 6 - 2. iscellnet screen shot
Figure 6 - 3. Hot boot concentrator
98-1031 Rev AA
Chapter 6 - Performing System Upgrades
55
Need help?