10 To reduce heat output, turn Hi/Lo Knob counterclockwise to desired temperature (see Error! Reference source not found.).
Heat output can be reduced by up to 11,000 BTUH (1/3). Blower can also be turned down.
NEVER "over fire" by increasing BTUH above nameplate specifications.
NEVER turn down (reduce) pilot flame below the minimum 325 millivolts.
11 Open windows for first two hours of operation.
NOTICE: Initial start -up will cause some NON -TOXIC "off gassing" of adhesives, binders, paint, etc. Most
nuisance odors will be
eliminated after the first 2 hrs. of operation, however, slight amounts may be present during the first 24
hrs.
5.5 TO TURN OFF GAS TO FIREPLACE
1.
Turn Thermostat to "OFF". Pilot will remain lit for return to normal service.
2. For complete shutdown turn Gas Cock Dial to "OFF".
3.
Turn off the internal manual shutoff valve in the appliance. See 3.4.6 Factory Installed Manual Gas Shutoff Valve.
85-03-01115
DXV35 TIMBERFIRE