Mendota DXV35 TIMBERFIRE Installation And Operating Instructions Manual page 44

Direct vent gas fireplace heater
Hide thumbs Also See for DXV35 TIMBERFIRE:
Table of Contents

Advertisement

Factory Installed Manual Gas Shutoff Valve
A manual gas shutoff valve is factory installed and located in the lower convection chamber. To operate the manual gas shutoff
valve, rotate the red shutoff handle clockwise to open and counterclockwise to close.
Gas Inlet Fittings Information
Caution: Before you run the gas line, read, understand and properly calculate the required gas line size.
Improper (too small) gas line size application can lead to improper burner ignition and can cause property
damage and/or injury. If you are not qualified or certified to run a gas line, do not proceed. Contact a
qualified Gas Plumber.
The gas inlet fitting supplied with this Fireplace provides a 3/8" female NPT fitting. This requires you to supply a 3/8" NPT male
fitting for connection to this appliance.
Based on the gas line size you have selected use an appropriate NPT fitting to adapt and connect to the 3/8" male NPT flex end
adapter.
85-03-01115
DXV35 TIMBERFIRE
Page 44

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxv45dt4Dxv42 timberfireM50Dxv60

Table of Contents