Clearance Requirements
Clearance from Appliance Body and Vent
Figure 3-21 CLEARANCES TO VENT
Figure 3-20 CLEARANCES TO BODY & VENT
The required clearances are depicted in these diagrams.
1. Minimum Clearance from fireplace body sides to combustibles is zero.
2. Minimum Clearance from fireplace top surface to combustibles is 2-1/2" or zero from top edge of top triangle
standoffs.
3. Minimum Clearance from vertical vent pipe sides to combustibles is 1".
4. Minimum Clearance below horizontal vent pipe or components is 1".
5. Minimum Clearance above elbows and horizontal vent pipe and components is 2".
85-03-01115
DXV35 TIMBERFIRE
Page 21