On fireplaces with electronic ignition system that come with a PF2 remote the convection fans function must be
programed out of the remote. This will ensure that the convection fans cannot be turned on. Follow the directions below
to remove the convection fans function from the remote.
1. Remove a battery from the remote.
2. Hold down both the ON/OFF key and MODE key
and reinstall the battery.
3. Continue to hold the ON/OFF key. Release the
MODE key. Press the MODE key once to highlight
the convection fan function.
4. While still holding the ON/OFF key press the DOWN
ARROW key. The display will change from "Set" to
"Clr" to indicate that the convection fan function
has been disabled.
5. Release the ON/OFF key.
3.2.7.3.1

Mendota Cool Wall

The Mendota Cool Wall system uses natural convection to take heat off the wall directly above the fireplace and redirects it up and
away from surrounding areas. Testing has shown that when using a Cool Wall system, temperatures above the fireplace are
reduced making it possible to mount a television 15" above the fireplace's top air gap.