6. Install the airbox and the burner in their original
locations and positions and secure down using screws
you removed earlier.
7. Make certain burner is running parallel to front face of
unit and positioned properly.
Next, the pressure regulator will be changed.
8. Using a ¼" flat blade screwdriver, remove 3 screws that
secure the NG Pressure Regulator to the gas valve body
and remove NG Pressure Regulator as shown above.
Identify the pressure regulator spring that is located in
the center of the black rubber gasket. Discard both the
black rubber gasket and spring.
9. Install the new LP Pressure Regular onto the gas valve
body in the same position and orientation as the NG
Pressure Regulator you removed in Step 2, above. The
LP Pressure Regulator can only be mounted in one
position. Secure the LP Pressure Regulator in place
using the 3 screws you removed in Step 2. Tighten
down using a ¼" flat blade screwdriver.
85-03-01115
Figure 4-10 Pilot Body
LP PRESSURE
REGULATOR
SCREWS
DXV35 TIMBERFIRE
GAS VALVE BODY
NG PRESSURE
REGULATOR