Maximum Horizontal Run
❑ Maximum Horizontal Run allowed is 12 feet if a vertical starter section that is between 4 feet to 25 feet is connected
directly to this fireplace's flue starter collar and no more than three (3) 90-degree elbows are used.
❑ Maximum Horizontal Run allowed is 12" if a 12" starter vertical section is connected directly to this fireplace's flue
starter collar.
Maximum Vent System Length
❑ Combined total length of all straight pipe sections in the vent system shall be less than 55 feet.
❑ Combined total length of all straight pipe sections in the vent system shall be less than 55 feet when using three (3) 90-
degree elbows or equivalent and terminating the vent system horizontally.
How to Calculate the Vent Lengths
For calculation purposes and usage of charts in this manual, simply add the lengths of all individual straight pipe sections. For
example: if you use two 2-foot lengths and one 4-foot length, the total vent system length will be 2+2+4 = 8 feet.
0
Using 90
Elbows
The DXV35 TIMBERFIRE Fireplace by MENDOTA allows maximum flexibility in the use of 90
length of the first straight vertical section directly connected to the fireplace's starter collar determines the maximum
horizontal run and the number of 90
For vent systems that provide a starting vertical section that is 4' to 25', you may connect up to 12' of horizontal pipe and up to
°
three 90
elbows.
°
Using 90
Elbows When the Initial Starter Vertical Section Is Less Than 4'
For vent systems that provide a starting vertical section less than 4' the following rules apply:
A. You must use the Master Venting Requirements Chart.
B. A single 90° vertical-to-horizontal elbow is already calculated into the allowable maximum horizontal run. The Venting
Requirements Chart assumes that for all horizontal runs calculated, one 90
Note: Each additional 90° elbow reduces the maximum horizontal distance allowed by 3'.
C. If you plan to use more than one 90
calculate the maximum horizontal run you are allowed based on the first vertical section connected directly to the
fireplace. From this maximum horizontal run calculated, subtract 3' for each additional 90
Caution: If a vertical-to-horizontal discharge elbow or a horizontal-to-horizontal discharge elbow is enclosed within a wall, floor or
ceiling, a top air space clearance of 2" must be maintained above the entire body of the elbow.
Using 45-Degree Elbows
Two 45-degree elbows may be used in place of one 90-degree elbow. On 45-degree runs, one foot of diagonal pipe is equal to
8-1/2 inches horizontal run and 8-1/2 inches vertical run. Two 45-degree elbows may be connected directly to the vent starter
adapter on this fireplace to create an offset to provide the required clearances to combustible framing or sheathing materials.
Two 45-degree elbows may be connected directly to the top of this fireplace to create a horizontal offset. 12 feet maximum
horizontal run allowed with this offset configuration only if the first vertical section connected directly to the last 45-degree
elbow is more than 4 feet to 25 feet long. For maximum allowable horizontal distances with the 45-degree offsets, see the
Master Venting Configuration Chart.
Note: Each horizontally positioned 45º elbow reduces the maximum horizontal distance by 1½ '.
SUPPORT: Horizontal runs of pipe will require one vent support for every 3 ft. of pipe.
85-03-01115
0
elbows allowed for this fireplace.
°
elbow within the vent system, first use the Venting Requirements Chart and
DXV35 TIMBERFIRE
o
elbows in the vent system. The
0
elbow is used within the venting system.
°
elbow you will use.
Page 56

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxv45dt4Dxv42 timberfireM50Dxv60

Table of Contents