Mendota DXV35 TIMBERFIRE Installation And Operating Instructions Manual page 41

Direct vent gas fireplace heater
Hide thumbs Also See for DXV35 TIMBERFIRE:
Table of Contents

Advertisement

OPERATING DURING POWER OUTAGES
This ignition system utilizes thermocouple and thermopile power for pilot and burner ignition functions. AC power is utilized for
blower function only. If the AC power is interrupted during a power outage, you may operate this fireplace for one continuous
hour on and one continuous hour off cycles only.
During the power outage, the appliance's burners will function. In addition, Flame Height adjustment function will be available.
The Fan, which is wholly dependent on 110VAC power, will not function.
Wall Thermostat System Diagram
RECOMMENDED MAXIMUM
LEAD LENGTH (TWO-WIRE)
WHEN USING WALL THERMOSTAT
(CP-2 SYSTEM)
WIRE SIZE
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
Figure 3-34 Thermostat Wiring Diagram
Note: Connect wires in junction box located on the left
side of this appliance to house power using supplied
wire nuts.
Replacement wires must have the same type and size of
insulation as the original.
85-03-01115
MAX. LENGTH
100 FT.
64 FT.
40 FT.
25 FT.
18 FT.
DXV35 TIMBERFIRE
This appliance must be electrically connected and
grounded in accordance with local codes or, in the
absence of local codes, with the current NFPA 70-
National Electric Code or CSA C22.1- Canadian Electrical
Code.
Label all wires prior to disconnection when servicing
control. Wiring Errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
Page 41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxv45dt4Dxv42 timberfireM50Dxv60

Table of Contents