Fireplace insert Features
EXTERNAL DIMENSIONS: 30-1/2" Wide X 19" High X 16-1/2" Deep
GLASS SIZE: NeoCeram Glass with non-reflective coating. Visible Glass measures 26-7/16" X 11-1/8".
MANTEL ALLOWANCE: 8" Deep Mantel at 12" Above Top Convection Opening (32-7/16" up from base of Unit)
CONTROLS: Thermocouple Safety System with Standing Pilot Thermopile power generator. Thermostat option available.
BLOWER SYSTEM: 190 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan Speed Controls
or Light Dimmers are allowed in same circuit.
BURNER SYSTEM: Stainless-Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS: Externally controllable Burner air shutter.
LOG SET: 6-piece, Premium Fiber Log Set with Extreme glow and realism.
REFRACTORY PANELS: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation.
NATURAL GAS INFORMATION: Factory equipped for Natural Gas. 4.5" WC Minimum inlet pressure required.
LPG INFORMATION: LP conversion kit # HA-28-00194 is required. 12" WC Minimum inlet pressure required. For the D30 LPG
application, the orifice is to be drill size #52. For higher altitude, adjustment to orifice size may be necessary.