OPERATING DURING POWER OUTAGES
This ignition system utilizes thermocouple and thermopile power for pilot and burner ignition functions. AC power is utilized for
blower function only. If the AC power is interrupted during a power outage, you may operate this fireplace insert for one
continuous hour on and one continuous hour off cycles only.
During the power outage, the appliance's burners will function. In addition, Flame Height adjustment function will be available
using the Hi-Lo knob on the main gas valve. The Fan, which is wholly dependent on 110VAC power, will not function.
Wall Thermostat System Diagram
RECOMMENDED MAXIMUM
LEAD LENGTH (TWO-WIRE)
WHEN USING WALL THERMOSTAT
(CP-2 SYSTEM)
WIRE SIZE
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
Figure 3-37 Thermostat Wiring Diagram
Replacement wires must have the same type and size of
insulation as the original.
85-03-01071
MAX. LENGTH
100 FT.
64 FT.
40 FT.
25 FT.
18 FT.
D30 DEEP TIMBER
This appliance must be electrically connected and
grounded in accordance with local codes or, in the
absence of local codes, with the current NFPA 70-
National Electric Code or CSA C22.1- Canadian Electrical
Code.
Label all wires prior to disconnection when servicing
control. Wiring Errors can cause improper and
dangerous operation. Verify proper operation after
servicing.