Leveling Bolts; Bolt - Mendota D30 Installation And Operating Instructions Manual

Direct vent gas fireplace insert heater
Table of Contents

Advertisement

4.3 LEVELING BOLTS

Leveling Bolts Definition
Four leveling bolts are included in the manual package. The leveling bolts allow for a ¼" minimum to 2" maximum leveling
ability. Leveling bolts are designed to adjust for uneven fireplace insert floors and yield plumb Insert Body. Use the leveling
bolts only if the fireplace insert floor is more than ¼" out of level from one side to another or from front to back. If the fireplace
insert floor is less than ¼" out of level, use metal sheet shims in various thickness and build up to needed leveling thicknesses at
various points around the appliance.
The leveling bolts supplied are designed specifically for application with this product. only use leveling bolts supplied by
Mendota and for leveling purposes only. Never use leveling bolts for purposes of lifting unit up to make up for ash lip heights or
other lifting or raising needs. Such use can cause extreme thermal expansion of firebox floor and can result in oil canning noise
or louder thermal expansion and constriction banging noise.
MENDOTA WARRANTY
Note: When lifting this Insert more than 1", other support blocks will be required. For all applications when
you raise the unit more than 1", reline the entire firebox floor with refr actory bricks to build up a full level
floor for the Insert to sit on. Do not use individual support block only under the four corners of this unit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury. Never use other
after-market leveling bolts. Doing so can lead to vibration noise problems or damage to internal
components.DO NOT USE LONGER BOLTS TO LIFT INSERT UPWAR D. THIS CAN CAUSE OTHER SIDE EFFECTS
LIKE HEAT EXPANSION/CONTRACTION NOISES. To lift Insert up, use Firebricks and mortar or a metal box
designed specifically for this purpose.
Leveling Bolts Installation
Perform this step after you have measured the firebox floor for level surface characteristics. Tip the Insert body on its back on
the wooden pallet. Thread one leveling bolt in to each leveling bolt receiving fastener. Thread the bolt in as far as necessary to
achieve the leveling effect desired.
85-03-01071
Figure 4-4 Leveling Bolts Installation
D30 DEEP TIMBER
SUCH NOISE PROBLEMS ARE NOT COVERED UNDER
Page 44

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D40 deep timber

Table of Contents