5288 V3 Server
User Guide
No. Compone
8
9
10
11
Issue 26 (2018-11-19)
Function
nt
RAID
Supported RAID controller cards:
controller
l SR120:
card
– Uses the LSI SAS2308 chip.
– Supports RAID 0, 1, 10, and 1E.
l SR130:
– Uses the LSI SAS3008 chip.
– Supports RAID 0, 1, 10, and 1E.
l SR430C:
– Uses the LSI SAS3108 chip.
– Supports RAID 0, 1, 10, 5, 50, 6, and 60.
– Supports a supercapacitor for power failure protection.
– Supports a maximum of 32 hard disks.
– Supports a cache of 1 GB or 2 GB.
l SR630C:
– Uses the LSI SAS3108 chip.
– Supports RAID 0, 1, 10, 5, 50, 6, and 60.
– Supports a supercapacitor for power failure protection.
– Supports 40 hard disks.
– Supports a cache of 1 GB or 2 GB.
These RAID controller cards support RAID level migration and drive
roaming.
NOTE
When you configure dual SAS adapters or SAS RAID controller cards for the
server, one of them must be a standard PCIe SAS adapter or SAS RAID
controller card.
TPM
l Complies with the Trusted Computing Group (TCG) standards.
(optional)
l Protects the platform from viruses or unauthorized operations.
DIMMs
l Up to 16 DDR4 RDIMMs or LRDIMMs, which provide a
maximum memory capacity of 2048 GB.
l Capacity per DIMM: 8 GB, 16 GB, 32 GB, 64 GB, or 128 GB.
l Memory speed: DDR4 1866 MT/s, 2133 MT/s, or 2400 MT/s
Heat sink
Dissipates heat from a CPU.
Each CPU is configured with one heat sink.