Huawei 5288 V3 V100R003 User Manual page 181

Table of Contents

Advertisement

5288 V3 Server
User Guide
Procedure
Step 1 Wear an ESD wrist strap. For details, see
Step 2 Determine the rack number and chassis number of the server to be removed, and label its
panel to prevent misoperations.
Step 3 Power off the 5288 V3. For details, see
Step 4 Remove all external cables such as power and network cables.
Step 5 Remove the 5288 V3 and put it on an ESD desktop. For details, see
Server.
Step 6 Remove the chassis cover. For details, see
Step 7 Remove full-height full-length riser cards if they are installed. For details, see
the Riser
Step 8 Remove the supercapacitor if it is installed. For details, see
Supercapacitor (RAID Controller
Step 9 Determine the position for installing the RAID controller card. See
Figure 7-57 Position of the RAID controller card
Step 10 Hold down the latches on the cables to the RAID controller card, and remove the cables from
the RAID controller card. For details, see
Step 11 Loosen the screws on the RAID controller card. See step (1) in
Issue 26 (2018-11-19)
Card.
Copyright © Huawei Technologies Co., Ltd.
1 Safety
Instructions.
4.2 Powering Off the
7.11 Removing the Chassis
Card).
2.7 Internal
Cabling.
7 Replacing Parts
Server.
3.6 Removing the
Cover.
7.19 Removing
7.33 Removing the
Figure
7-57.
Figure
7-58.
171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents