TEST 7B
REPAIRING INSTRUMENT CLUSTER PRINTED CIRCUIT BOARD WARNING LAMP
Perform TEST 7A Before Proceeding
START TEST 7B.
REMOVE AND INSPECT
THE INOPERATIVE
WARNING LAMP.
*Perform Verification TEST VER-2A.
TURN IGNITION OFF.
REMOVE THE
INSTRUMENT
CLUSTER.
**Check connectors - Clean / repair as necessary.
315
IS THE INOPERATIVE
NO
LAMP CRUISE OR
TRAC ON?
YES
IS THE LAMP
NO
CONDITION OK?
YES
REPLACE THE
INSTRUMENT
CLUSTER.*
REPLACE THE LAMP.*
REPLACE THE
INSTRUMENT
CLUSTER.*
I
N
S
T
R
U
M
E
N
T
C
L
U
S
T
E
R